The largest database of trusted experimental protocols

Mouse specific elisa kits

Manufactured by Thermo Fisher Scientific
Sourced in France, United States

Mouse-specific ELISA kits are lab equipment used to detect and quantify specific proteins or analytes in mouse samples, such as serum, plasma, or cell culture supernatants. The kits utilize the Enzyme-Linked Immunosorbent Assay (ELISA) technique to provide accurate and reliable measurements of the target analytes.

Automatically generated - may contain errors

5 protocols using mouse specific elisa kits

1

Quantifying Cytokine Profiles Using ELISA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Measurements of IL-2, IL-6, IL-10, IL-13, IL-17A, TNF-α,and IFN-γ were performed by specific mouse ELISA kits from eBiosciences (Thermo Fisher Scientific, Villebon-Sur-Yvette, France). Concentrations were calculated from a standard curve according to the protocol of the manufacturer.
+ Open protocol
+ Expand
2

Macrophage and Lymphocyte Cytokine Secretion

Check if the same lab product or an alternative is used in the 5 most similar protocols
Spleen cell suspensions (2.106 cells/well) were seeded in 12-well plates and incubated for 3 hours for the adhesion of macrophages; then the supernatant containing the lymphocytes was collected and placed in another 12-well plate. Macrophages and lymphocytes were cultured with complete RPMI medium with 10% heat-inactivated FBS, 1% streptomycin-penicillin, 1% sodium pyruvate, 1% ciprofloxacin and 1% fungizone. Macrophages were stimulated for 48 hours with a final concentration of 100 ng/mL LPS (from E. coli serotype 0127: B8 from Sigma Aldrich #L319) and lymphocytes for 72 hours with a final concentration of 5 µg/mL of concanavalin A (Sigma-Aldrich, Saint-Quentin Fallavier, France). The supernatant was collected and stored at -80°C.
Assessment of IL-17A, IL-6 and TGF-β was performed using specific mouse ELISA kits from eBiosciences (Invitrogen - ThermoFisher Scientific, France). Concentrations were calculated from a standard curve according to the manufacturer’s protocol.
+ Open protocol
+ Expand
3

Quantitative Serum Immunoassay for Murine Brucellosis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mouse serum immunoglobulin G (IgG) and interferon gamma (IFN-γ) titers were measured using an enzyme-linked immunosorbent assay (ELISA) in 96-well ELISA plates (Nunc-immuno MaxiSorb, Sigma). Total mouse serum IgG, IgG1, and IgG2a titers were measured using mouse-specific ELISA kits by following manufacturer's instructions (eBioscience). To determine Brucella-specific IgG titers, ELISA plates were coated with 100 μL of heat-killed bacterial suspensions prepared in PBS (OD600=2.0) from B. abortus grown for 2 days on SBA. Cultures were heat-killed at 65°C for 1 hour, cooled to room temperature, and treated with kanamycin (50 μg/mL) and gentamycin (50 μg/mL) to prevent bacterial growth. Serum IFN-γ titers were measured using the OptiEIA mouse IFN-γ ELISA kit (BD Biosciences) following the manufacturer’s instructions. The signal from all ELISA plates were measured at 450 nm with a 570 nm background correction using a Tecan Infinite M200 PRO fluorescence plate reader. All values presented are the mean ± the standard error of the mean (SEM) from at least 5 mice for each time-point and condition.
+ Open protocol
+ Expand
4

Quantifying Spinal Inflammatory Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
After homogenizing the L4–L6 spinal dorsal horns (SDHs) with the tissue protein extraction (T-PER) reagent, the supernatant was collected after 15 min of centrifugation at 4°C and 4000 rpm. The mouse-specific ELISA kits (eBioscience, USA) were utilized to assess interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-α), as per the guidelines of the manufacturer for sealing, adding samples, incubating, and developing color. The optical density (OD) was measured at 450 nm using a microplate reader (VarioSkan Flash, Thermo Fisher Scientific, USA). The results are presented as pg/mg of protein following the protein level normalization based on the standard curve [10 (link)].
+ Open protocol
+ Expand
5

Cytokine Profiling in BALF

Check if the same lab product or an alternative is used in the 5 most similar protocols
The concentrations of IL-17A, IL-6, IL-21, IFN-γ, IL-18 and IL-23 in BALF of mice were measured using mouse-specific ELISA kits, according to the manufacturer´s instructions (eBioscience, CA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.