Spd m10avp uv vis photodiode array detector

Manufactured by Shimadzu
Sourced in Japan

The SPD-M10Avp is a UV/Vis photodiode-array detector for liquid chromatography applications. It features a deuterium and tungsten-halogen lamp as light sources, and a photodiode-array detector for simultaneous multi-wavelength data acquisition. The detector has a wavelength range of 190 to 800 nm.

Automatically generated - may contain errors

4 protocols using spd m10avp uv vis photodiode array detector

1

Quantitative Analysis of Compounds by RP-HPLC-ESI-TOF/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The HPLC system consisted of LC-10ADvp pumps and an SPD-M10Avp UV-vis photodiode-array detector (Shimadzu, Kyoto, Japan). For the RP-HPLC, an Inertsil ODS-3 octadecylsilane column of 4.6 × 250 mm and particle size 5 µm (GL Sciences, Tokyo, Japan) was used. The eluent was 20 mM ammonium acetate (pH 7.0) containing acetonitrile. The acetonitrile concentration was increased from 0 to 14% during 40 min in linear gradient mode. The column temperature was 40°C and the flow rate was 1 ml/min. The electrospray ionization time of flight mass spectrometry (ESI-TOF/MS) measurements were performed on a MicroTOF spectrometer (Bruker, Bremen, Germany) in negative mode.
+ Open protocol
+ Expand
2

HPLC-MS-NMR Analysis of Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
An HPLC system including an SPD-M10Avp UV/Vis photodiode-array detector (Shimadzu, Kyoto, Japan) with an Inertsil ODS-3 octadecylsilane column of size 4.6 × 250 mm and particle size of 5 μm (GL Sciences, Tokyo, Japan) was used. The eluent was 20 mM ammonium acetate (pH 7.0) containing methanol. The methanol concentration was increased from 0 to 50% over 30 min in linear gradient mode. The column temperature was 40°C and the flow rate was 1 mL/min. The RP-HPLC chromatogram was detected at 200–500 nm. ESI-TOF-MS and HR-ESI-TOF-MS measurements were performed on a MicrOTOF spectrometer (Bruker, Bremen, Germany) in negative mode. The sample isolated by RP-HPLC was directly infused into the MS system by a syringe pump without a column. The NMR spectra were obtained on a JNM-ECA500 spectrometer (JEOL, Tokyo, Japan).
+ Open protocol
+ Expand
3

HPLC-MS Analysis of Modified Nucleosides

Check if the same lab product or an alternative is used in the 5 most similar protocols
The HPLC system consisted of LC-10ADvp pumps and an SPD-M10Avp UV-Vis photodiode-array detector (Shimadzu, Kyoto, Japan). For the RP-HPLC, an Inertsil ODS-3 octadecylsilane column of size 4.6 × 250 mm and particle size of 5 μm (GL Sciences, Tokyo, Japan) was used. The eluent was 20 mM ammonium acetate (pH 7.0) containing acetonitrile. For AcdGuo, the acetonitrile concentration was increased from 0 to 30% over 45 min in linear gradient mode. For AcdAdo, the acetonitrile concentration was increased from 0 to 37.5% over 45 min in linear gradient mode. The column temperature was 40 °C and flow rate was 1 mL/min. The RP-HPLC chromatogram was detected at 200–500 nm. ESI-TOF/MS measurements were performed on a MicrOTOF spectrometer (Bruker, Bremen, Germany) in negative mode. The sample isolated by RP-HPLC was directly infused into the MS system by a syringe pump without a column.
+ Open protocol
+ Expand
4

UV-Vis and RP-HPLC Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Transmittance and absorption spectra were obtained by a MultiSpec-1500 UV/Vis spectrometer (Shimadzu, Kyoto, Japan). The UV/Vis spectra were measured at room temperature in the wavelength range of 200–800 nm. An HPLC system including an SPD-M10Avp UV/Vis photodiode-array detector (Shimadzu) with an Inertsil ODS-3 octadecylsilane column of 4.6 × 250 mm and particle size of 5 μm (GL Sciences, Tokyo, Japan) was used. The eluent was 20 mM ammonium acetate (pH 7.0) containing methanol. The methanol concentration was increased from 0 to 50% over 15 min, and maintained at 50% from 15 to 30 min. The column temperature was 40°C and flow rate was 1 ml/min. The reversed phase (RP)-HPLC chromatogram was detected at 200–500 nm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!