The largest database of trusted experimental protocols

Competitive elisa kits

Manufactured by Elabscience
Sourced in China

Competitive ELISA kits are laboratory tools designed to detect and quantify the presence of specific analytes in a sample. They work on the principle of competitive binding, where the analyte of interest competes with a known amount of labeled analyte for binding to a limited number of antibody binding sites. The resulting signal is inversely proportional to the concentration of the analyte in the sample.

Automatically generated - may contain errors

2 protocols using competitive elisa kits

1

Oxidative Stress Biomarkers Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Following the manufacturer’s instructions, urinary and serum 8-OHdG were analysed in duplicates using highly sensitive and competitive ELISA kits (ab201734; Abcam, Shanghai, China). Serum concentrations were determined by comparison to a standard curve and recorded in ng/l. The intra-and-inter assay coefficients of variation (CV) were 3.5% and 4.5%, respectively. Urinary 8-OHdG concentrations obtained from the standard curves were normalised to creatinine concentrations and recorded as ng/mg Cr.
Serum 8-epi-PGF2α was analysed in duplicate using competitive ELISA kits from Elabscience, Shanghai, China (cat. LogE-EL-0041). The intra-and-inter assay CV were 5.6% and 6.4%, respectively. The absorbance of both 8-epi-PGF2α and 8-OHdG was read at 450 nm on a microplate reader (Bio-Tek ELx808 microplate reader, Hayward, CA, USA).
TAC reagents were obtained from Sigma-Aldrich (Hong Kong, China). Plasma samples were thawed to measure TAC spectrophotometrically at 593 nm using Mindray BA-88A, Wuhan, Hubei, China. The estimation of TAC was based on ferric reducing ability of plasma by following the manufacturer’s instructions. The absorbance was used to obtain the concentrations after comparison to standard curves and recorded in µmol/l.
+ Open protocol
+ Expand
2

Oxidative Stress Biomarkers Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Following the manufacturer's instructions, urinary and serum 8-OHdG were analysed in duplicates using highly sensitive and competitive ELISA kits (ab201734, Abcam, China). Serum concentrations were determined by comparison to a standard curve and recorded in ng/L. The inter-and-intra assay coefficients of variation (CV) were 3.5% and 4.5%, respectively. Urinary 8-OHdG concentrations obtained from the standard curves were normalised to creatinine concentrations and recorded as ng/mg Cr. Serum 8-epi-PGF2α was analysed in duplicate using competitive ELISA kits from ELabscience, China (cat. LogE-EL-0041). The intra-and-inter assay coefficients of variation (CV) were 5.6% and 6.4%, respectively. The absorbance of both 8-epi-PGF2α and 8-OHdG was read at 450nm on a microplate reader (Bio-Tek ELx808 microplate reader, Hayward, CA, USA). TAC reagents were obtained from Sigma-Aldrich (Hong Kong, China). Plasma samples were thawed to measure TAC spectrophotometrically at 593 nm using Mindray BA-88A, China. The estimation of TAC was based on ferric reducing ability of plasma (FRAP) and the protocol as described by Benzie and Strain [32] . The absorbance was used to obtain the concentrations after comparison to standard curves and recorded in µmol/l.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!