The largest database of trusted experimental protocols

Opsys mr system plate reader

Manufactured by Dynex

The Opsys MR system plate reader is a laboratory equipment that is used to measure and analyze various samples in a microplate format. It is designed to perform absorbance, fluorescence, and luminescence measurements. The Opsys MR system provides accurate and reliable data for a wide range of applications in life science research and drug discovery.

Automatically generated - may contain errors

2 protocols using opsys mr system plate reader

1

Quantitative VEGF165 ELISA Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
VEGF165a capture antibody, at a concentration of 0.25  μg/ml, was incubated on high-binding 96-well plates overnight at room temperature. The plates were blocked (1% BSA in PBS) and serial dilutions of recombinant human (rh)VEGF165 standards (ranging from 500 pg/ml to 1.95 pg/ml) were added, incubated alongside sample lysates, typically 200 μg in 100 μl per well. The plate was incubated for 2 h at room temperature with shaking, washed and incubated with 100 μl/well of biotinylated goat anti-human VEGF (0.1 μg/ml; R&D systems) for 2 further hours at room temperature. After washing, 100 μl/well of Horseradish Peroxidase (HRP)-conjugated streptavidin (1:200; R&D Systems) was added and plates were left at room temperature for 20 min. The plates were washed and color change induced with substrate A and B (DY-999; R&D Systems) for 1 h under light protection. The reaction was stopped by addition of 100 μl/well of 1 M HCl and the absorbance was read immediately in an ELISA plate reader (Dynex Technologies Opsys MR system plate reader) at 450 nm with a control reading at 620 nm. A standard curve was calculated from mean absorbance values of standards enabling the estimation of VEGF concentration for each sample.
+ Open protocol
+ Expand
2

VEGF Quantification by ELISA

Check if the same lab product or an alternative is used in the 5 most similar protocols
PanVEGF capture antibody (1 μg ml−1) (Duoset VEGF ELISA DY-293; R&D Systems, Minneapolis, MN, USA) was incubated overnight at room temperature. The plates were blocked (Superblock; Thermo Scientific) and serial dilutions of recombinant human (rh)VEGF165 or rhVEGF165b standards (ranging from 4 ng ml−1 to 16.25 pg ml−1) were added, incubated alongside sample lysates, typically diluted 1 : 10. The plate was incubated for 1 h at 37 °C with shaking, washed and incubated with 100 μl per well of either biotinylated goat anti-human VEGF (0.1 μg ml−1; R&D Systems) or mouse anti-human VEGF165b (0.25 μg ml−1) for a further 1 h at 37 °C. After washing, 100 μl per well of horseradish peroxidase (HRP)-conjugated streptavidin (1 : 200; R&D Systems) was added and plates were left at room temperature for 20 min.
The plates were washed and colour change was induced with substrate A and B (DY-999; R&D Systems) for 20 min under light protection. The reaction was stopped by addition of 100 μl per well of 1 M H2SO4 and the absorbance was read immediately in an ELISA plate reader (Dynex Technologies Opsys MR system plate reader) at 450 nm with a control reading at 570 nm. Revelation Quicklink 4.25 software (Dynex Technologies, Chantilly, VA, USA) was also used to calculate a standard curve from mean absorbance values of standards enabling the estimation of VEGF concentration for each sample.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!