The largest database of trusted experimental protocols

2 protocols using myoglobin from human heart

1

Investigating Effects of Compounds on rTth Polymerase

Check if the same lab product or an alternative is used in the 5 most similar protocols
Different concentrations of NaCl (Sigma, Steinheim, Germany), CaCl2·2H2O (Sigma, Neu-Ulm, Germany), FeCl3·6H2O (Merck, Darmstadt, Germany), disodium EDTA·2H2O (Sigma, Steinheim, Germany), trisodium citrate·2H2O (Sigma, Vienna, Austria), sodium heparin (Novo, Vienna, Austria), sodium dodecyl sulfate (SDS, Merck, Darmstadt, Germany), proteinase K (Ambion, Kaufungen, Germany), urea (Sigma, Steinheim, Germany), bile salts (Sigma, Steinheim, Germany), hemoglobin and lactoferrin from human blood (Sigma, Steinheim, Germany), bovine IgG (Sigma, Steinheim, Germany), and myoglobin from human heart (Sigma, Steinheim, Germany) were prepared in DEPC treated water to investigate their effects on rTth polymerase to detect RNA. The final concentrations in the real-time RT-PCR mixtures were 10, 20, 40, 60, 80, 100 mM NaCl; 6, 8, 10, 12, 14, 16 mM CaCl2; 0.01, 0.1, 0.5, 1, 5, 10 mM FeCl3; 1, 2, 4, 6, 8, 10 mM EDTA; 1, 5, 10, 20, 40, 60 mM citrate; 1, 5, 10, 20, 40, 60 IU heparin; 10, 20, 50, 100, 150, 200 μg/ml SDS; 5, 10, 20, 40, 60, 80 μg/ml proteinase K; 50, 100, 150, 200, 300, 400 mM urea; 10, 50, 100, 200, 500, 1000 μg/ml bile salts; 5, 10, 20, 50, 100, 200 μg/ml lactoferrin; 0.1, 0.2, 0.5, 1, 2, 5 mg/mL hemoglobin; 10, 20, 50, 100, 200, 300 μg/ml IgG; 30, 60, 90, 120, 300, 600 μg/ml myoglobin.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Functionalized Nanomaterials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Poly(ethylene glycol (PEG, Mw = 5000 g/mol) was obtained from JenKem Technology USA, MPTES ((3-Mercaptopropyl)triethoxysilane), cetyltrimethylammonium bromide (CTAB), cetyltrimethylammonium chloride(CTAC), ascorbic acid, sodium borohydride (NaBH4), silver nitrate (purity >99%), 4-aminothiophenol (pATP), glutaraldehyde (GA), chloroauric acid (HAuCl4), myoglobin from human heart (Mw = 17.7 kDa), albumin from bovine serum (Mw = 66.5 kDa), albumin from human serum (Mw = 65 kDa), and hemoglobin (Mw = 64.5 kDa) were obtained from Sigma-Aldrich. All the chemicals have been used as received with no further purification. The protein blocking solution (Odyssey Blocking Buffer (PBS)) was purchased from LI-COR Biosciences, Lincoln, NE.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!