2 protocols using cd45.1 pe cy7 clone a20

1

Multiparameter Flow Cytometry Immunophenotyping

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following antibodies were used for cell surface staining: anti-mouse CD4-Alexa700 (clone GK1.5), CD8-APC-eFluor780 (clone 53–6.7), CD25-eFluor450 or PerCPCy5.5 (clone PC61.5), Vα2TCR-PerCP eFluor710 or APC (clone B20.1), Vα3.2TCR-FITC (clone RR3-16), CD45.1-PE-Cy7 (clone A20), CD45.2-FITC (clone 104) (eBioscience), or CD4-redfluor710, CD8-APC-Cy7 (Tonbo Bioscience), and Neuropilin-1-PE (clone 3E12) (Biolegend). Cell proliferation dye eFluor450 staining was performed at 2 μM for 10 min at 37 °C (eBioscience). For intracellular staining: Nur77-PE (clone 12.14), and Foxp3-PE (clone FJK-16s) or -APC were used (eBioscience). Cells were first surface stained for 15 min on ice, followed by fixation and permeabilization according to manufacturer’s instructions using Foxp3 Transcription Factor staining buffer set (eBioscience). Flow cytometry was performed using a BD Fortessa or Fortessa X20 analyzer (BD Bioscience), and data were analyzed using FlowJo software (Treestar).
+ Open protocol
+ Expand
2

Multiparameter Flow Cytometry Immunophenotyping

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following antibodies were used for cell surface staining: anti-mouse CD4-Alexa700 (clone GK1.5), CD8-APC-eFluor780 (clone 53–6.7), CD25-eFluor450 or PerCPCy5.5 (clone PC61.5), Vα2TCR-PerCP eFluor710 or APC (clone B20.1), Vα3.2TCR-FITC (clone RR3-16), CD45.1-PE-Cy7 (clone A20), CD45.2-FITC (clone 104) (eBioscience), or CD4-redfluor710, CD8-APC-Cy7 (Tonbo Bioscience), and Neuropilin-1-PE (clone 3E12) (Biolegend). Cell proliferation dye eFluor450 staining was performed at 2 μM for 10 min at 37 °C (eBioscience). For intracellular staining: Nur77-PE (clone 12.14), and Foxp3-PE (clone FJK-16s) or -APC were used (eBioscience). Cells were first surface stained for 15 min on ice, followed by fixation and permeabilization according to manufacturer’s instructions using Foxp3 Transcription Factor staining buffer set (eBioscience). Flow cytometry was performed using a BD Fortessa or Fortessa X20 analyzer (BD Bioscience), and data were analyzed using FlowJo software (Treestar).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!