The largest database of trusted experimental protocols

Magnetom tim trio 3 tesla scanner

Manufactured by Siemens
Sourced in Germany

The Magnetom TIM Trio 3 Tesla scanner is a magnetic resonance imaging (MRI) system manufactured by Siemens. It operates at a field strength of 3 Tesla, which provides high-resolution images for medical diagnostic purposes. The system is designed to capture detailed anatomical and functional information about the human body.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using magnetom tim trio 3 tesla scanner

1

Multimodal Brain Imaging Protocol for Faces/Places Task

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI data were acquired using a Siemens Magnetom TIM Trio 3 Tesla scanner and 32-channel head-coil. Sagittal T1-weighted anatomical images were acquired using a MPRAGE sequence (TR = 1,900 ms; TE = 2.32 ms; inversion time = 900 ms; flip angle = 9°; sagittal slice thickness = 0.9 mm; in-plane = 0.449 × 0.449 mm; matrix = 512 × 512; field-of-view = 230 × 230). To enhance resolution, a multi-band sequence was used to collect a total of 286 oblique-axial echo planar imaging (EPI) volumes during the faces/places task (multiband acceleration = 6; TR = 1,000 ms; TE = 39.4 ms; flip angle = 36.4°; slice thickness = 2.2 mm, number of slices = 60; in-plane resolution = 2.1875 × 2.1875 mm; matrix = 96 × 96). Images were collected in the oblique axial plane (approximately −20° relative to the AC-PC plane) to minimize susceptibility artifacts. To enable fieldmap correction, two oblique-axial spin echo (SE) images were collected in each of two opposing phase-encoding directions (rostral-to-caudal and caudal-to-rostral) at the same location and resolution as the functional volumes (i.e., co-planar; TR = 7,220 ms; TE = 73 ms).
+ Open protocol
+ Expand
2

High-Resolution T1-weighted MRI Acquisition

Check if the same lab product or an alternative is used in the 5 most similar protocols
Structural MRI images were acquired using a Siemens Magnetom Tim Trio 3 Tesla scanner (Siemens AG, Erlangen, Germany) with a 32‐channel head coil at the Murdoch Children's Research Institute (Royal Children's Hospital, Victoria, Australia). High‐resolution T1‐weighted images were taken (192 slices, 0.9‐mm slice thickness, 0.8‐mm in‐plane resolution, TE = 2.59 msec, TR = 1900 msec, flip angle = 9°).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!