Thunder imager tissue microscope

Manufactured by Leica camera
Sourced in Germany

The THUNDER Imager Tissue is a microscope designed for high-resolution imaging of tissue samples. It provides advanced optical capabilities, enabling detailed visualization and analysis of cellular structures and morphology.

Automatically generated - may contain errors

3 protocols using thunder imager tissue microscope

1

Nissl Staining for DG Volume

Check if the same lab product or an alternative is used in the 5 most similar protocols
A randomly chosen series was used to calculate the total volume of the DG in each animal using Nissl staining. Slices were mounted on 2% gelatine-coated glass slides and air-dried at rt for 48 h. The slides were sequentially immersed in the following solutions: 6 min in toluidine blue, 10 sec in bi-distilled water, 2 min in EtOH 70°, 2 min in EtOH 96°, 2 min in EtOH 100°, 2 min in EtOH 100°, and 2 min in Xylene (PanReac, #251769). Next, sections were embedded in DePex (Serva Electrophoresis™, #1824301) and dried for 48 h at rt before imaging. Images were acquired under a THUNDER Imager Tissue microscope equipped with a Leica DFC9000 GTC VSC-09991 camera (Leica Microsystems Ltd., Wetzlar, Germany) and using a 5X dry objective. Images were processed using the Leica Application Suite X (LAS X) software provided by the manufacturer (Leica Microsystems Ltd., Wetzlar, Germany). The DG volume was determined using the freehand selection tool in Fiji software to measure the granule cell layer (GCL) plus the SGZ area on each section of the series. Each area was multiplied by the thickness of the tissue (namely 50 µm) and by the sampling fraction (8). The numbers obtained were summed to calculate the total DG volume, which is expressed in mm3.
+ Open protocol
+ Expand
2

Morphological and Molecular Analyses of Photoaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
For the morphological evaluation, 12 μm RST sections were stained with hematoxylin and eosin (H&E) according to the standard protocol.
To quantify the melanin content, 12 μm thick RST sections were subjected to Fontana–Masson staining. The sections were then treated with a 2.5% aqueous silver nitrate solution for 10 min, 0.2% aqueous gold chloride for 1 min, and 5% aqueous sodium thiosulfate for 5 min. The melanin levels were normalized by counterstaining the epidermis with fast red.
To detect the expression of photoaging-related proteins, 12 μm frozen sections were hydrated in distilled water, subjected to antigen retrieval by heating in a citrate buffer (pH 6), and blocked with 3% bovine serum albumin (Sigma-Aldrich) prepared in PBS. The sections were incubated overnight in a humidified chamber at 4 °C with the following primary antibodies: anti-TRP-2 (1:100), anti-filaggrin (1:100), anti-collagen type I (1:500), and anti-laminin-5 (1:200). The sections were then incubated for 2 h with secondary antibodies, namely 1:1000 Alexa Fluor 488 goat anti-rabbit IgG (Abcam) or Alexa Fluor 555 goat anti-mouse IgG (Abcam); diluted in PBS; and mounted using a mounting medium containing 4′,6-diamidino-2-phenylindole (DAPI). Images were obtained using a Leica THUNDER Imager Tissue microscope and analyzed using the ImageJ Software.
+ Open protocol
+ Expand
3

Confocal Imaging of Cornea and Lacrimal Gland

Check if the same lab product or an alternative is used in the 5 most similar protocols
LG images were acquired using Zen Black software (version 2.3 SP1, Zeiss, France) on an LSM 880 confocal microscope (Zeiss, France). Whole LG section images were obtained using a 20×/0.8 objective while co-immunostaining of GFP with E-cadh or Krt19 proteins were observed via 0.36-μm step size z stacks using a 63×/1.4 oil immersion objective. Images were then processed with Zen Black software (version 2.3 SP1, Zeiss) and Zen Blue lite software (version 3.2, Zeiss). Whole-cornea images were acquired using the navigator module on a Leica Thunder Imager Tissue microscope with the large volume computational clearing (LVCC) process. Images were obtained using a 20×/0.55 objective with LAS X software (3.7.4) and processed with Imaris Bitplane software (version 9.8.0). All of the images from a single panel were acquired and processed with the same parameters.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!