The largest database of trusted experimental protocols

Labsystems multiskan ms spectrophotometer

Manufactured by Thermo Fisher Scientific
Sourced in Finland

The Labsystems Multiskan MS is a spectrophotometer designed for absorbance measurements in microtiter plates. It features a built-in microplate reader and performs absorbance measurements across the visible and UV spectral range.

Automatically generated - may contain errors

3 protocols using labsystems multiskan ms spectrophotometer

1

SDS-Based Protein Extraction and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Discs containing SC samples were placed in 10 mL of 0.1% SDS and were sonicated for 2 min. Then, samples were centrifuged for 10 min at 4 °C, and 5500 rpm. Next, samples were dried and re-dissolved in 2 mL ultra-pure water. Protein concentration was determined using the Pierce BCA Protein Assay Kit (ThermoFisher Scientific, Waltham, MA, USA) according to the manufacturer’s instruction in 96 well plastic plates. A 0.1% SDS was used as negative control. The protein measurement was performed at 595 nm wavelength on a Labsystems Multiskan MS spectrophotometer (ThermoFisher Scientific, Waltham, MA, USA).
+ Open protocol
+ Expand
2

Serum CCL17 Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The blood sample was collected from the radial or femoral artery after sheath insertion before coronary angiography for serum CCL17 testing. The serum was isolated by centrifugation 3000rpm,10min and was frozen at -80℃ immediately until CCL17 measurement. Serum CCL17 level was tested via the Quantikine ELISA kit for human CCL17 (R&D Systems, Minneapolis, MN, USA) according to the manufacture's instruction.
The result was read through Labsystems Multiskan MS spectrophotometer (Thermo Labsystems Oy, Helsinki, Finland).
+ Open protocol
+ Expand
3

Serum CCL17 Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The blood sample was collected from the radial or femoral artery after sheath insertion before coronary angiography for serum CCL17 testing. The serum was isolated by centrifugation 3000rpm,10min and was frozen at -80℃ immediately until CCL17 measurement. Serum CCL17 level was tested via the Quantikine ELISA kit for human CCL17 (R&D Systems, Minneapolis, MN, USA) according to the manufacture's instruction. The result was read through Labsystems Multiskan MS spectrophotometer (Thermo Labsystems Oy, Helsinki, Finland).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.