The largest database of trusted experimental protocols

Nanodrop bca protein software

Manufactured by Thermo Fisher Scientific
Sourced in United States

The NanoDrop BCA PROTEIN software is a tool that enables the determination of protein concentration using the Bicinchoninic Acid (BCA) assay. It provides a spectrophotometric method for quantifying protein levels in a sample.

Automatically generated - may contain errors

2 protocols using nanodrop bca protein software

1

Quantification of Plastoglobule Proteins

Check if the same lab product or an alternative is used in the 5 most similar protocols
Isolated plastoglobules in sucrose fractions were purified and concentrated in TrE buffer (5 mM Tricine-KOH, pH 7.5, 0.2 mM EDTA, and 0.2 mM dithiothreitol) using disposable ultrafiltration devices (Vivaspin 500 Concentrators, Sartorius Stedim Biotech GmbH, Goettingen, Germany). First, 400 µL of deterged fractions were precipitated as described previously [78 (link)], with slight modification; obtained PG proteins were resuspended in 10 µL in TrE buffer, and the BCA protein assay kit for low concentrations (ab207002, Abcam, Cambridge, UK) was used to quantify the protein content. The assay was performed according to the manufacturer’s instructions. An equal volume of every sample was added to the BCA working reagents, and the reactions were incubated for 120 min at 37 °C. Absorbance was read at 562 nm on a NanoDrop 2000/2000c Spectrophotometer (Thermo Fisher Scientific Inc., Waltham, MA, USA). Protein concentrations were calculated using bovine serum albumin (BSA) standards and a four-parameter logistic curve using NanoDrop BCA PROTEIN software (v. 1.6, Thermo Fisher Scientific Inc., Waltham, MA, USA).
+ Open protocol
+ Expand
2

Quantitative Protein Analysis via BCA Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
A BCA protein assay kit for low concentrations (ab207002, Abcam, Cambridge, UK) was used to quantify the protein content. The assay was performed according to the manufacturer’s instructions. A volume of 50 µL from every thylakoid sample was added to the BCA working reagents, giving a final reaction volume of 200 µL. The reactions were incubated for 120 min at 37 °C. Absorbance was read at 562 nm on a NanoDrop 2000/2000c Spectrophotometer (Thermo Fisher Scientific Inc., Waltham, MA, USA). Protein concentrations were calculated using bovine serum albumin (BSA) standards and a four-parameter logistic curve using the NanoDrop BCA PROTEIN software (v.1.6, Thermo Fisher Scientific Inc., Waltham, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.