Ge lunar prodigy primo full densitometer

Manufactured by GE Healthcare
Sourced in United States

The GE Lunar Prodigy Primo Full Densitometer is a medical imaging device used to measure bone density. It utilizes dual-energy X-ray absorptiometry (DXA) technology to assess bone mineral content and density, providing information about bone health.

Automatically generated - may contain errors

5 protocols using ge lunar prodigy primo full densitometer

1

Body Composition and Bone Density Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Body mass and body height were measured using a certified medical digital scale WB-3000 (TANITA Corporation, Tokyo, Japan), with an accuracy of 0.01 kg, and a mechanical measuring rod for body height HR-001 (TANITA Corporation, Tokyo, Japan), with an accuracy of 0.5 cm.
Dual-energy X-ray absorptiometry (DXA) body composition and bone mineral density (BMD) measurements were performed on an empty stomach using a GE Lunar Prodigy Primo Full Densitometer with the enCore Body Composition option (GE Healthcare Technologies, USA). The assessment of BMD was performed total body, left hip (total femur and femoral neck), and lumbar spine. All scans were acquired by the same technician. The short-term reproducibility of the applied DXA device has been shown to be 2.1% for total body, 1.1% for lumbar spine and 1.6% for femoral neck.
+ Open protocol
+ Expand
2

Comprehensive Body Composition Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
Body mass and height were measured using a certified digital medical scale (model WPT 80/150.O; Radwag, Radom, Poland), with an accuracy of 0.01 kg, and a mechanical measuring rod to measure body height, with an accuracy of 0.5 cm.
Dual-energy X-ray absorptiometry (DXA) body composition and BMD measurements were performed on an empty stomach using a GE Lunar Prodigy Primo Full Densitometer with the enCore Body Composition option (GE Healthcare Technologies, USA). The assessment of BMD were acquired for the total body, lumbar spine (L1–L4) and left hip (total femur and femoral neck). All measurements were performed one week before the start of the marathon.
+ Open protocol
+ Expand
3

Body Composition Assessment Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Body mass was measured using a certified medical digital beam scale WB-3000 (TANITA Corporation, Tokyo, Japan). Body height was measured using a measurement rod HR-001 (TANITA Corporation, Tokyo, Japan). Body composition was assessed before the first meal of the day using a densitometry device GE Lunar Prodigy Primo Full Densitometer (GE Healthcare Technologies, Boston, MA, USA).
+ Open protocol
+ Expand
4

Body Composition and Aerobic Capacity Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
One week prior to the start of the experiment, the body composition and aerobic capacity of each participant were measured. Body mass and body height were measured using a certified medical digital beam scale WB-3000 (TANITA Corporation, Tokyo, Japan), with an accuracy of 0.01 kg, and a mechanical measuring rod for body height HR-001 (TANITA Corporation, Tokyo, Japan), with an accuracy of 0.5 cm. Body composition was measured in the fasting state using a GE Lunar Prodigy Primo Full Densitometer with enCore Body Composition option (GE Healthcare Technologies, USA). BMI was calculated by dividing body mass (kg) by the square of body height (m2).
+ Open protocol
+ Expand
5

Body Composition Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Body mass, height, and body composition were measured before and after the 4-week study. The subjects were weighed naked using a certified medical digital beam scale WB-3000 (TANITA Corporation, Tokyo, Japan) before and after exercise training in group ET and before and after exercise training and after sauna in group ET + S. Body composition was measured in the fasting state using a GE Lunar Prodigy Primo Full Densitometer with enCore Body Composition option (GE Healthcare Technologies, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!