600mhz avance 1 spectrometer

Manufactured by Bruker

The 600MHz Avance I spectrometer is a nuclear magnetic resonance (NMR) spectrometer designed for high-resolution analysis of chemical samples. It operates at a frequency of 600MHz, enabling precise measurement and characterization of molecular structures and properties.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using 600mhz avance 1 spectrometer

1

Fluorine NMR Compound Titration

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 19F-NMR measurements were done at 20°C using 3mm tubes containing 200 μl of sample on a Bruker 600MHz Avance I spectrometer equipped with a CP-QCI-F cryoprobe with Fluor Cryo-detection. 19F-NMR experiments were done on control samples with compound 1 or compound 16 at 50μM, 37.5μM, 25μM, 12.5μM and 6.25μM, in a 50mM Hepes 100mM NaCl buffer with a constant percentage (1%) of DMSO. The 19F titration experiments were carried out on samples containing 50μM, 37.5μM, 25μM, 12.5μM and 6.25μM of compounds (1 and 16) with a constant enzyme concentration of 5μM in the same buffer. The carrier frequency was set at −100 ppm with a spectral window of 40 ppm, and 4024 scans were recorded per sample, except for the 6.25μM sample for which 12288 scans were recorded.
+ Open protocol
+ Expand
2

Quantitative 19F NMR Titration Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 19F NMR measurements were done at 20 °C using 3 mm tubes containing 200 μl of sample on a Bruker 600 MHz Avance I spectrometer equipped with a CP-QCI-F cryoprobe with Fluor Cryo-detection. 19F NMR experiments were done on control samples with compound 1 or compound 16 at 50 μM, 37.5 μM, 25 μM, 12.5 μM and 6.25 μM, in a 50 mM Hepes 100 mM NaCl buffer with a constant percentage (1%) of DMSO. The 19F titration experiments were carried out on samples containing 50 μM, 37.5 μM, 25 μM, 12.5 μM and 6.25 μM of compounds (1 and 16) with a constant enzyme concentration of 5 μM in the same buffer. The carrier frequency was set at −100 p.p.m. with a spectral window of 40 ppm, and 4,024 scans were recorded per sample, except for the 6.25 μM sample for which 12,288 scans were recorded.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!