Serum uric acid values were measured photometrically with a Cobas 6000 from Roche Diagnostics (Mannheim, Germany, with reagent uricase, enzymatic test, coefficient of variation (CV) 1.3%). This method is standardized against ID/MS. Cystatin C was determined by immunonephelometry on a Behring Nephelometer (BN) II (Siemens, Erlangen, Germany) (CV low concentrations 3.3, high conc. 2.0%). Adiponectin and leptin concentrations in maternal and cord blood serum were determined by a commercially available ELISA (R&D Systems, Wiesbaden, Germany), high sensitivity CRP (hs-CRP, Immunodiagnostik AG, Bensheim, Germany, CV low conc. 5.4%, high conc. 4.0%) and retinol-binding protein 4 (RBP4), measured by immunonephelometry on a BNII (Siemens, Erlangen, Germany, CV 4.3%). HbA1c, HDL, triglyceride and insulin were measured according to routine methods in the university laboratory.
S monovette 7.5 ml serum gel tubes
The S-Monovette 7.5 ml serum-gel tubes are a laboratory equipment product designed for the collection and storage of blood samples. The tubes contain a gel separator that allows for the separation of serum from the blood sample during centrifugation.
Lab products found in correlation
1 protocol using s monovette 7.5 ml serum gel tubes
Maternal-Fetal Biomarker Profiling
Serum uric acid values were measured photometrically with a Cobas 6000 from Roche Diagnostics (Mannheim, Germany, with reagent uricase, enzymatic test, coefficient of variation (CV) 1.3%). This method is standardized against ID/MS. Cystatin C was determined by immunonephelometry on a Behring Nephelometer (BN) II (Siemens, Erlangen, Germany) (CV low concentrations 3.3, high conc. 2.0%). Adiponectin and leptin concentrations in maternal and cord blood serum were determined by a commercially available ELISA (R&D Systems, Wiesbaden, Germany), high sensitivity CRP (hs-CRP, Immunodiagnostik AG, Bensheim, Germany, CV low conc. 5.4%, high conc. 4.0%) and retinol-binding protein 4 (RBP4), measured by immunonephelometry on a BNII (Siemens, Erlangen, Germany, CV 4.3%). HbA1c, HDL, triglyceride and insulin were measured according to routine methods in the university laboratory.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!