The largest database of trusted experimental protocols

Vasculocis

Manufactured by PerkinElmer
Sourced in France

Vasculocis is a lab equipment product designed to analyze vascular function. It provides quantitative measurements of vascular parameters.

Automatically generated - may contain errors

3 protocols using vasculocis

1

Lymphoscintigraphy Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lymphoscintigraphy was performed according to a procedure described in detail elsewhere.13 In short, 20 MBq technetium-99m–labeled human serum albumin (Tc-99m-HSA (Vasculocis; CIS Bio International, Paris, France) in 0.1 mL was injected in the finger web between the second and third fingers bilaterally and was followed immediately by dynamic imaging for 30 minutes. Sequential 300-second scans were performed every 30–45 minutes for 5 hours using a dual head Philips Skylight gamma camera equipped with low-energy, high-resolution collimators.
+ Open protocol
+ Expand
2

Lymphatic Clearance Imaging in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
All mice underwent weekly micro-computed tomography (µ-CT) scans of both hindlimbs for repetitive volume assessments. Smallanimal single-photon emission computed tomography (SPECT)/CT was performed as in an earlier described model [19] . In brief, mice were scanned on a Siemens INVEON multimodality preclinical scanner (Siemens Preclinical Solutions, Knoxville, TN, USA). The projection was set to 1200 ms and the transaxial field of view was 44 mm. Before every imaging session, mice were anesthetized with a mixture of 1.5-2.0% isoflurane and 100% oxygen and placed in prone position on a heated SPECT/CT animal bed.
Two mice per group (six in total) underwent Technetium 99 m human serum albumin ( 99 Tc-HSA) lymphoscintigraphy at weeks 1 and 6 to assess the lymphatic clearance. Mice were injected subcutaneously with a bolus injection of 0.02 mL 99m Tc-HSA between each hindlimb's second and third toe. Doses were approximately 14.9 ± 1.9 MBq for left hindlimb and 15.1 ± 1.5 MBq for right hindlimb (Vasculocis, CIS Bio International, Paris, France) administered using a 0.5 mL 30-gauge syringe (Covidien, Medtronic Minneapolis, USA). The tracer uptake was expected to have reached steady state after 45 min [21] (link). The SPECT/CT was performed after 45 min and 4 h after injection of 99m Tc-HSA and moved around freely between imaging sessions.
+ Open protocol
+ Expand
3

SPECT-Lymphoscintigraphy for Lymphatic Flow

Check if the same lab product or an alternative is used in the 5 most similar protocols
CT and single-photon emission computed tomography (SPECT)-lymphoscintigraphy was performed following a previously described model [13] with minor modifications. Briefly, the scans were performed on a Siemens INVEON multimodality pre-clinical scanner (Siemens pre-clinical solutions, Knoxville, TN, US). The minor modifications included the projection which was set to 1200 ms (950 ms previously) and the transaxial field of view which was 44 mm (38 mm previously). Through each imaging session, the animals were anesthetized with a mixture of 1.5-2% isoflurane and 100% oxygen and placed front feet first in a prone position on a heated SPECT/CT animal bed (38 mm wide).
The animals received an injection of 0.02 ml 99m Tc-HSA subcutaneously between the second and third toe to measure the lymphatic removal rate. The mean radioactive activity was approximately 14.9 ± 1.9 MBq for the left hindlimb and 15.1 ± 1.5 for the right MBq (Vasculocis, CIS Bio International) and administered using a 0.5 ml 30 G insulin syringe (Covidien) under general anesthesia with a mixture of 1.5-2% isoflurane and 100% oxygen.
After 45 min the tracer was assumed to have reached a steady flow with a constant removal rate [18] . Mice underwent SPECT-lymphoscintigraphy at 45 min and 4 h after injection of 99m Tc-HSA and moved around freely between image sessions.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!