The largest database of trusted experimental protocols

Mouse antihuman cd14 fitc

Manufactured by BioLegend
Sourced in United States

Mouse antihuman CD14-FITC is a fluorescently-labeled monoclonal antibody that binds to the CD14 antigen expressed on the surface of human monocytes and macrophages. It can be used for the identification and enumeration of these cell populations by flow cytometry.

Automatically generated - may contain errors

2 protocols using mouse antihuman cd14 fitc

1

Analyzing Human M1 and M2 Macrophages

Check if the same lab product or an alternative is used in the 5 most similar protocols
We used heparin sodium anticoagulation tubes to collect 5 ml of peripheral blood, and then took several test tubes. Add antibody PI (10 μl)/CD45-cyanine7 (1 μl)/IgG2b-CY5.5 (1 μl)/IgG1-APC (1 μl) (Biolegend Corp., San Diego, CA, USA) to each tube of 100 μl whole blood as a negative control group. PI(10 μl)/CD45-cyanine7(1 μl)/CD86-CY5.5(1 μl)/CD163-APC(1 μl) (Biolegend Corp., San Diego, CA, USA) was used as the experimental group. Add 1 ml of hemolysin to each test tube. The target cell gate can be set more accurately in the FS/SS graph of the flow cytometer. In CD45/SS flow cytometry, the monocyte gate can be set more precisely. Using a three-color scheme, select the CD45/SS map to set a gate, and detect high expression of CD14 (macrophages) in the blood. As per the antibody manufacturer's instructions, human M1 and M2 macrophages were expressed by adding fluorescently labeled mouse antihuman CD14-FITC, CD86-PE-Cyanine5, and CD163-APC monoclonal antibody reagents (10 μL; Biolegend Corp., San Diego, CA, USA). The mixtures were mixed well and allowed to react in a refrigerator at 4°C for 30 min. The mixtures were centrifuged at 1500 rpm for 5 min to remove the supernatants. The obtained cell deposits were resuspended in PBS for flow cytometry analysis.
+ Open protocol
+ Expand
2

Quantifying M1/M2 Macrophage Phenotype

Check if the same lab product or an alternative is used in the 5 most similar protocols
The expression levels of M1 and M2 macrophage polarization markers CD86, CD163, and CD206 were detected by flow cytometry. In 100 μL of peripheral blood anticoagulated with heparin sodium, we added mouse anti-human CD14-FITC, CD86-PE-Cyanine5, CD163-APC, and CD206-PE (Biolegend, San Diego, CA, USA) to 10 μL respectively. After the sample was mixed well, it was incubated in the dark at room temperature for 20 min, followed by the addition of red blood cell lysate. Further, each sample was shaken and incubated in the dark at room temperature for 15 min, followed by flow cytometry measurements. Then, the forward scatter (FSC) was taken as the abscissa and the longitudinal scatter as the ordinate (SSC) to develop a scatter plot. The lymphocyte gate was set, and then the boundary fluorescence marker was determined. The results were analyzed with Flow Jo 7.6.1 software.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!