The largest database of trusted experimental protocols

Lc 10atvp binary pump

Manufactured by Shimadzu
Sourced in Japan

The LC-10ATvp binary pump is a high-performance liquid chromatography (HPLC) pump designed for reliable and accurate solvent delivery. It features two independent solvent lines, allowing for the precise blending of two different solvents. The pump operates at pressures up to 40 MPa (400 bar, 5,800 psi) and supports flow rates ranging from 0.001 to 10.000 mL/min. The LC-10ATvp provides stable and pulseless flow, ensuring consistent performance in HPLC applications.

Automatically generated - may contain errors

2 protocols using lc 10atvp binary pump

1

HPLC Analysis of Carotenoids: Zeaxanthin and Lutein

Check if the same lab product or an alternative is used in the 5 most similar protocols
The LC-10A HPLC (Shimadzu, Kyoto, Japan) was equipped with LC-10ATvp binary pump (Shimadzu, Kyoto, Japan), SIL-10A autosampler (Shimadzu, Kyoto, Japan), and SPD-M10Avp detector (Shimadzu, Kyoto, Japan). The instrument was controlled by a computer and the Lab Solutions (Shimadzu, Kyoto, Japan) chromatography workstation was used to analyze the data. To obtain better chromatographic peaks of zeaxanthin and lutein, various mobile phase systems were optimized, and the optimal chromatographic separation conditions were determined. The Shimadzu® C18 column (4.6 mm × 250 mm, 5 μm; Kyoto, Japan) was used for the analysis of the zeaxanthin and lutein contents. The optimum chromatographic conditions for the flow rate, detection wavelength, column temperature, and the injection volume were selected as 1.0 mL/min, 450 nm, 25 °C, and 20 μL, respectively. The mobile phase consisted of acetonitrile/dichloromethane (95:5, v/v).
+ Open protocol
+ Expand
2

UHPLC-MS/MS Analysis of Yuanhuacine

Check if the same lab product or an alternative is used in the 5 most similar protocols
A DGU-20A 5R series UHPLC system equipped with a LC-10ATvp binary pump (SHIMADZU, Japan) was used for UHPLC–MS/MS analysis. A 5500 triple quad tandem mass spectrometer equipped with electrospray ionization source (AB Sciex, Concord, OH, Canada) was used for mass spectrometry. The mobile phase was composed of a mixture of 0.1% formic acid aqueous solution (A) and acetonitrile (B) with a gradient elution program (0–0.1 min, 40% B; 0.1–2.5 min, 40–95% B; 2.5–3.5 min, 95% B; 3.5–4.5 min, 95–40% B; 4.5–5.0 min, 40% B). The flow rate was set at 0.3 mL/min and the injection volume was 5 µL. The ESI source was operated in positive ionization mode. The mass spectrometer was operated in multiple reactions monitoring (MRM) mode and the selected monitor ions were m/z 649.4/151.1 for yuanhuacine and m/z 748.5/590.4 for IS. The optimized parameters were as follows: ion source temperature (TEM), 550 °C; curtain gas (CUR), 35 psi; ion source gas 1 (GAS1), 55 psi; ion source gas 2 (GAS2), 55 psi; ion spray voltage (IS), 5500 V.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.