Manufactured by Thermo Fisher Scientific

The Orbitrap Q-Exactive High-Field mass spectrometer is a high-resolution, high-mass-accuracy mass spectrometer. It combines a quadrupole mass analyzer with an Orbitrap mass analyzer for accurate mass measurements and high-resolution MS and MS/MS data acquisition.

Automatically generated - may contain errors

2 protocols using orbitrap q exactive high field mass spectrometer

1

HPLC-MS/MS Analysis of Methanolic Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
Liquid chromatography was performed on a Vanquish HPLC system controlled by Chromeleon software (ThermoFisher Scientific) and coupled to an Orbitrap Q-Exactive High-Field mass spectrometer controlled by Xcalibur software (ThermoFisher Scientific). Methanolic extracts prepared as described above were separated on a Thermo Hypersil Gold C18 column (150 mm × 2.1 mm, particle size 1.9 μM, part no. 25002-152130) maintained at 40 °C with a flow rate of 0.5 mL/min. Solvent A is 0.1% formic acid (Fisher Chemical Optima LC/MS grade; A11750) in water (Fisher Chemical Optima LC/MS grade; W6-4); solvent B is 0.1% formic acid in acetonitrile (Fisher Chemical Optima LC/MS grade; A955-4). A/B gradient started at 1% B for 3 min after injection and increased linearly to 98% B at 20 min, followed by 5 min at 98% B, then back to 1% B over 0.1 min, and finally held at 1% B for the remaining 2.9 min to reequilibrate the column (28 min total method time). Mass spectrometer parameters were spray voltage, −3.0 kV/+3.5 kV; capillary temperature, 380 °C; probe heater temperature, 400 °C; sheath, auxiliary, and sweep gas, 60, 20, and 2 AU, respectively; S-Lens RF level, 50; resolution, 120,000 at m/z 200; and AGC target, 3E6. Each sample was analyzed in negative (ESI−) and positive (ESI+) electrospray ionization modes with m/z range 100 to 1,000.
+ Open protocol
+ Expand
2

LC-MS/MS Analysis of Methanolic Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
Liquid chromatography was performed on a Vanquish HPLC system controlled by Chromeleon Software (ThermoFisher Scientific) and coupled to an Orbitrap Q-Exactive High Field mass spectrometer controlled by Xcalibur software (ThermoFisher Scientific). 2 μL of the methanolic extract prepared as described above was injected and separated on a Thermo Hypersil Gold C18 column (150 mm × 2.1 mm, particle size 1.9 μM) maintained at 40°C with a flow rate of 0.5 mL/min.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!