The largest database of trusted experimental protocols

Ge pet ct dste scanner ge discovery ste

Manufactured by GE Healthcare
Sourced in United States

The GE PET-CT DSTe scanner is a medical imaging device that combines positron emission tomography (PET) and computed tomography (CT) technologies. It is designed to capture detailed images of the body's physiological processes and anatomical structures.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using ge pet ct dste scanner ge discovery ste

1

Multimodal Brain Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All participants underwent fMRI scanning with a 3.0T MRI scanner (Achieva, Philips Medical System, Best, Netherlands) to obtain T2*-weighted single-shot echo-planar imaging sequences with the following parameters: 165 axial volume scans: voxel size, 2.75 × 2.75 × 3.0 mm3; slice number, 31 (interleaved); matrix, 80 × 80; slice thickness, 3.0 mm; gap, 1.0 mm; repetition time (TR), 2000 ms; echo time (TE), 30 ms; and field of view (FOV), 220 mm. Subjects were instructed to rest and keep their eyes closed without sleeping, moving, or thinking about anything specific for 5 min 30 s.
A 3D-T1-turbo field echo sequence was also obtained with the following parameters: axial acquisition with FOV, 220 mm; voxel size, 0.98 × 0.98 × 1.2 mm3; TR, 9.6 ms; TE, 4.6 ms; flip angle, 8°; no gap; and total acquisition time, 5 min 29.3 s.
DAT scans were performed with a GE PET-CT DSTe scanner (GE Discovery STE, GE Healthcare Technologies, Milwaukee, WI), which obtained images with a 3D-resolution of 2.3 mm thickness at half-maximum. All participants fasted for at least 6 h before DAT scanning. Each patient received 5 mCi (185 MBq) of 18F-FP-CIT intravenous injection, and images were acquired in the 3D mode at 120 KVp and 380 mAs during a 20-min session that took place 90 min after each injection.
+ Open protocol
+ Expand
2

Dopamine Transporter PET Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 18F-FP-CIT PET scans were performed using a GE PET-CT DSTe scanner (GE Discovery STE, GE Healthcare Technologies, Milwaukee, WI, USA), which obtains images with a three-dimensional resolution of 2.3 mm full width at half-maximum. All subjects fasted for at least 6 hours before the PET scan. After fasting, 5 mCi (185 MBq) of 18F-FP-CIT was injected intravenously, and the images were acquired in the three-dimensional mode at 120 KVp and 380 mAs during a 20-minutes session, performed at 90 minutes after injection.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!