The largest database of trusted experimental protocols

Cy5 annexin 5 antibody

Manufactured by BD

The Cy5 Annexin V antibody is a fluorescent-labeled antibody that binds to phosphatidylserine, a cellular membrane component that is exposed during apoptosis. This antibody can be used to detect and quantify the level of apoptosis in cell populations.

Automatically generated - may contain errors

2 protocols using cy5 annexin 5 antibody

1

Annexin V Apoptosis Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Apoptosis assays were performed using a Cy5 Annexin V antibody according to the manufacturer’s instructions (BD Biosciences). Stained cells were filtered with a 40μm mesh and analyzed on a FACSCanto II flow cytometer using DIVA software.
+ Open protocol
+ Expand
2

Detecting UVB-Induced Apoptosis by Flow Cytometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
For Cy5 Annexin V (BD Biosciences) and DAPI staining followed by flow cytometry analysis, equal numbers of N/TERT, SINCE and SINEG2 cells were seeded in 6-cm dishes, and collected either 24 or 48 h after plating, or were collected after 24 h of mock treatment or UVB treatment for 24 h in order to detect UVB-induced apoptosis. Culture media from each of UVB-treated culture dishes were also collected to include any detached dead or apoptotic cells that may be floating in the medium. After centrifugation, cells were resuspended in 100 μl of 1 × Annexin V-binding buffer solution (BD Biosciences) and 5 μl Cy5 Annexin V antibody (BD Biosciences) or without antibody (negative controls). Resuspended cells were then gently vortexed and were incubated for 15 min at room temperature in the dark. Next, 400 μl of 1 × Annexin V-binding buffer solution (BD Biosciences) was added per sample and samples were kept on ice. Finally, DAPI (Sigma-Aldrich) was added at a final concentration of 200 ng/ml per sample, 1–2 min before the cells were given for flow cytometry analysis, where the same number of events was acquired for each sample (20 000–30 000 events). Samples were analysed in duplicates.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!