The largest database of trusted experimental protocols

Rapitex rf

Manufactured by Siemens
Sourced in United States

RapiTex RF is a lab equipment product from Siemens. It is designed for rapid testing and analysis of materials.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using rapitex rf

1

Serological Biomarkers in Rheumatoid Arthritis

Check if the same lab product or an alternative is used in the 5 most similar protocols
IgM rheumatoid factor (RF) was measured using RapiTex RF (Dade Behring Inc, Newark DE, USA) (positive ≥40 IU/ml). Anti-CCP2 antibodies were measured using QuantaLite™, Inova Diagnostics (San Diego, CA, USA) using titer levels as suggested by the manufacturer (positive >20.0 U/ml) or, since 2009, using the EuroImmun assay (positive >5.0 U/ml). As both the EuroImmun and the Inova assays use the same enzyme linked immunosorbent assay (ELISA) plates coated with the same antigens (as do all other antibodies to cyclic citrullinated peptide, second generation (anti-CCP2) assays across the world), have similar sensitivity and specificity, and give linear results across a wide range of concentrations, their results are easily interconvertible using the following logarithmic transformation:
Inova anti-CCP2 = –26.44 + 28.86 * ln(EuroImmun anti-CCP2).
The anti-Sa/citrullinated vimentin in-house ELISA was described previously (positive threshold ≥0.20 optical density units) [16 (link)]. From 2012 on, we used a commercial anti-Sa assay (EuroImmun; positive >19 RU/ml), validated against our in-house ELISA [17 ].
+ Open protocol
+ Expand
2

Rheumatoid Factor and Anti-CCP2 Antibody Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
IgM RF was measured using RapiTex RF, Dade Behring Inc, Newark DE (positive (RF) ≥40 IU/mL); anti-CCP2 antibodies using QuantaLite, Inova Diagnostics, San Diego CA, according to the manufacturer’s instructions (positive (ACPA) >20.0 U/mL) or, since 2009, using EuroImmun assay (positive >5.0 U/mL). The two assays use the same antigen plates, and their results are easily interconvertible using a logarithmic equation.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!