The largest database of trusted experimental protocols

3 protocols using ferulic

1

Standardized Phytochemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The standard compounds and reagents (all of analytical grade): MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), DMSO (dimethyl sulfoxide), gallic acid, Na2CO3, 1,1-diphenyl-2-picrylhydrazyl radical (DPPH), Folin-Ciocalteu’s reagent, resazurin, tetracycline, chloramphenicol, kanamycin, acetonitrile (LC-MS grade, gradient grade), formic acid, 4-methoxybenzoic acid, 4-hydroxy-3-methoxycinnamaldehyde, caffeic acid, quercetin, luteolin and pinostrobin PBS were purchased from Merck (Darmstadt, Germany). The standards of 4-hydroxybenzoic acid, p-coumaric acid, ferulic, isoferulic acid, pinobanksin, chrysin, sakuranetin, naringenin, apigenin, kaempferol, isorhamnetin, acacetin and pinocembrin were obtained from Extrasynthese (Genay, France) and galangin from Alfa Aesar, (Haverhill, MA, USA). The antibiotics: ampicillin, oxacillin, teicoplanin, gentamicin, amikacin, fusidic acid, erythromycin, mupirocin, rifampicin, levofloxacin, norfloxacin, linezolid, bacitracin were purchased from Argenda (Poland). Methanol, ethanol, vanillin, benzoic acid, cinnamic acid were purchased from (POCH, Gliwice, Poland). Ultrapure H2O (18.0 MΩ) was obtained with a Milli-Q Advantage A10 system (Millipore, Billerica, MA, USA). The absorbance of the reaction mixture in Folin-Ciocalteu, DPPH assays were measured using a Genesys 20 spectrophotometer (Thermo Scientific, Waltham, MA, USA).
+ Open protocol
+ Expand
2

Analytical Standards Preparation and Recombinant Enzyme Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ethanol, hexane and formic acid of analytical reagent grade were from Sigma-Aldrich (Steinheim, Germany). Acetonitrile of HPLC and HPLC-MS grade were purchased from Panreac (Barcelona, Spain). The Milli-Q-system (Millipore SA, Molsheim, France) was used to produce deionized water. Pinoresinol (≥ 95%) and pcoumaric acid (≥ 98%) from Sigma-Aldrich (Steinheim, Germany) were used as standard compounds. Other standards as vanillic, ferulic and syringic acids, Eresveratrol, tyrosol, and kaempferol were purchased from Extrasynthese (France).
Human recombinant PTP-1B was expressed in Escherichia coli TB1 strain, and purified as previously described (Paoli et al., 2013) . 4-nitrophenyl phosphate disodium salt hexahydrate were from Santa Cruz Biotechnology.
+ Open protocol
+ Expand
3

HPLC Analysis of Phenolic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC-grade acetonitrile was purchased from Fisher Scientific (Lisbon, Portugal). Formic acid was purchased from Prolabo (VWR International, France). The phenolic compound standards (ferulic, sinapic, p-coumaric and caffeic acids, and kaempferol-3-O-rutinoside, quercetin-3-O-rutinoside, and quercetin-3-O-glucoside) were purchased from Extrasynthese (Genay, France). All other chemicals were of analytical grade and were purchased from common sources. Water was treated in a Milli-Q water purification system (Millipore, model A10, Billerica, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!