The largest database of trusted experimental protocols

Cobas e601 kit

Manufactured by Roche
Sourced in United States

The Cobas e601 kit is a laboratory equipment product manufactured by Roche. It is designed for automated immunoassay analysis. The core function of the Cobas e601 kit is to perform immunochemical tests on patient samples.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using cobas e601 kit

1

Bone Metabolism Markers and Bone Density

Check if the same lab product or an alternative is used in the 5 most similar protocols
The same measurements were performed at baseline and after four months. Height and weight were measured wearing light clothing and no shoes, and fasting blood samples were drawn. Serum calcium and creatinine, PTH, 25(OH)D, blood glucose, serum insulin and HbA1c and homeostatic model assessment for insulin resistance (HOMA-IR) were calculated as previously described [13 (link)]. BMI was calculated as weight (kg) divide by height (m) squared.
CTX-1 and P1NP were measured by electrochemiluminescence immunoassays with a Cobas e601 kit (Roche Diagnostics, NJ, USA), at the Hormone Laboratory, Oslo University Hospital, Norway. DKK1, leptin, OPG, sclerostin, TNF-α were analyzed using multianalyte profiling Milliplex MAP assay, and RANKL by a single analyte assay (Millipore Corporation, Billerica, MA, USA).
BMD was measured by DXA (GE Lunar Prodigy, Lunar Corporation, Madison, WI, USA) at the hip and lumbar spine, with total hip (mean of left and right, or one side if not both could be measured) and L1 (which had valid measurement in almost every subject) used in the analyses.
+ Open protocol
+ Expand
2

Hepatitis B Diagnostic Biomarkers

Check if the same lab product or an alternative is used in the 5 most similar protocols
A one-off sample of approximately 3-5 mL of venous blood was collected from each subject. All serum specimens were stored at 4 °C before testing. HBsAg, anti-HBs, HBeAg, anti-HBe and anti-HBc were detected by an electrochemiluminescence method using a Roche Cobase 601 Kit (Roche, Indianapolis, IN, USA). Serum T-Bil, AST, ALT and HBV-DNA concentrations were measured by standard clinical laboratory techniques.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!