Rf 5301 pc fluorescence spectrofluorophotometer

Manufactured by Shimadzu
Sourced in Japan

The RF-5301 PC fluorescence spectrofluorophotometer is a versatile laboratory instrument designed for fluorescence analysis. It provides accurate and reliable measurements of fluorescent samples across a wide range of applications.

Automatically generated - may contain errors

2 protocols using rf 5301 pc fluorescence spectrofluorophotometer

1

Fluorescence and FTIR Spectroscopy Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The fluorescence measurements were performed on a Shimadzu RF-5301 PC fluorescence spectrofluorophotometer (Kyoto, Japan). A 1 cm path length quartz cuvette was used in the experiment. The widths of the excitation and emission slits were set to 5.0 and 5.0 nm, respectively. The Fourier Transform Infrared (FTIR) spectrum was recorded in the range 400–4000 cm−1 on KBr (FTIR IRAffinity-1s, Shimadzu, Japan). The pH measurements were performed by a PHS-25 pH meter (Shanghai INESA Scientific Instrument Co. Ltd, China). The purified water was obtained from a SMART-N Heal Force Water Purification System (Shanghai Canrex Analytic Instrument Co., Ltd, Pudong Shanghai China).
+ Open protocol
+ Expand
2

Comprehensive Characterization of Synthesized Photocatalysts

Check if the same lab product or an alternative is used in the 5 most similar protocols
Investigation of crystalline nature of as synthesized materials was done using D8 Bruker X-ray Diffractometer varying the incident angle from 20° to 80° using Cu-Kα radiation (λ = 1.5418 nm). XPS measurements were performed in ultra-high vacuum conditions using standard Omicron system equipped with monochromatic Al Kα 1486.7 eV X-ray source operated at 15 KeV at constant analyzer energy of 100 eV for survey scans and 20 eV for detailed scans. Morphology of fabricated photocatalysts was examined by scanning electron microscope (Hitachi S-4800 microscope operated at 20 kV) and JEOL-2100 TEM. The SEM was fitted with EDAX for elemental mapping of the synthesized materials. Raman spectroscopy was performed with a home-made confocal setup fitted with a 532 nm laser. The measurements were performed at 1 mW of excitation power and spectra recorded using an iHR550 imaging spectrometer (from Horiba Scientific). Surface area was calculated through nitrogen physisorption with Nova 2200e (Quantachrome). Diffuse reflectance was recorded in the wavelength ranging from 200 to 800 nm with PerkinElmer, Lambda 750 UV–Vis–NIR spectrophotometer, equipped with integrating sphere. Energy band gap of synthesized photocatalysts were calculated by Kubelka-Munk equation. Room Temperature PL spectra were measured with RF-5301 PC Fluorescence Spectrofluorophotometer (Shimadzu, Japan).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!