The largest database of trusted experimental protocols

Eurospher 100 5

Manufactured by Knauer
Sourced in Germany

Eurospher 100-5 is a high-performance liquid chromatography (HPLC) column. It is filled with silica-based packing material with a particle size of 5 micrometers. The column is designed for use in analytical and preparative HPLC applications.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using eurospher 100 5

1

HPLC Analysis of Diazinon Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analysis of the samples was performed utilizing a KNAUER Azura MWD 2.1 L high-performance liquid chromatography (HPLC) system, incorporating a C18 column (4.6 mm × 250 mm, 5 μm) (model: Eurospher 100-5, Knauer, Azura, Germany). The mobile phase was HPLC-grade methanol and distilled water (10:90 v/v) with a flow rate of 1 mL min−1. The injection volume was 20 μl and monitored at 245 nm to detect diazinon. During the analysis, the column temperature was maintained at room temperature.
+ Open protocol
+ Expand
2

HPLC Quantification of Opioid Peptides

Check if the same lab product or an alternative is used in the 5 most similar protocols
Microdialysis samples were measured with a Knauer high-performance liquid chromatograph (HPLC) with ultraviolet (UV) detection and a Smart line pump (1000). The β-EP and MENK separation were carried out isocratically with a Knauer reverse phase C18 column (vertex plus 250 × 4.6 mm Eurospher100-5) with guard cartridge and a Knauer CTO-6A column oven. The system was used at oven temperature (40 °C) with detection at 210 nm. The flow rate was set at 0.2 mL/min to elute samples of the column. Solvents were degassed under vacuum. The buffer was KH2PO4 (68 mL) and acetonitrile (32 mL) 0.1 M (pH 2.3). The mobile phase was acetonitrile/buffer in the first 4 min, acetonitrile/water from 4 to 6 min, and acetonitrile/buffer from 6 to 12 min (temperature 40 °C). Plotting of graphs and data analyses were performed with Autochro data module software. The concentrations of each sample were calculated by interpolating the areas obtained after fraction injection with those obtained from three known standard concentrations (met-enk from Abcam and β-end from Sigma-Aldrich, dissolved in normal saline) injected regularly into the HPLC to monitor the linearity of the system. Integration of chromatographic data was performed with Perkin-Elmer 1020 software [41 (link)].
+ Open protocol
+ Expand
3

Phytochemical Quantification via HPLC-PDA

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Waters liquid chromatography device coupled with a Photodiode Array Detector (PDA) and C18 column (Knauer, 25 cm × 4.6 mm Eurospher 100-5) was used for phytochemical quantification of the plant materials (the aerial and underground parts) according to Esmaeili et al.27 (link).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!