The largest database of trusted experimental protocols

7 protocols using lucirin tpo l

1

UV-Curable Coatings with POSS Molecules

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

Coating solutions made from the blend of MA0736 POSS™ molecules (available from Hybrid Plastics Inc., Hattiesburg, Miss.), CN991 (aliphatic urethane acrylate from Sartomer, Exton, Pa.), CN2303 (alkoxylated multifunctional acrylate oligomer from Sartomer), tetrahyhydrofurfuryl alcohol (TFHA) and Lucirin™ TPO-L (photoinitiator, available from BASF) were applied to primed PET film and cured by UV source. The coated film was then treated with oxygen plasma for 90 seconds. The % reflection was measured and reported with the formulations and treatment conditions in Table 4.

TABLE 4
Reflection results of plasma treated samples of Example 3
Formulation (wt %)O2 plasmaAverage % R
CN991/CN2303TPO-treatment time(400-800
SampleCN991(70:30)THFAMA0736L(seconds)nm)
160881002903.37
170871012902.89
180851032902.65
190831052902.03
200811072901.44
2107810102901.01
2207310152900.9
2306810202900.73

+ Open protocol
+ Expand
2

Immunoglobulin G Extraction and Proteomic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Pentaerythritol-tetrakis(3-mercaptopropionate) (“tetrathiol”), triallyl-1,3,5-triazine-2,4,6-(1H,3H,5H)-trione (“triallyl”), 2-(boc amino) ethanethiol, and methanol (99.8%) were obtained from Sigma-Aldrich (Brøndby, Denmark). Lucirin TPO-L was obtained from BASF (Ludvigshafen, Germany). Acetonitrile (ACN), trifluoroacetic acid (TFA), DL-dithiothreitol (D9779, DTT), iodoacetamide (I670-9, IAA), immunoglobulin G (56,834-25MG, IgG, from human serum), trypsin (T1426, from bovine pancreas), and salts were purchased from Sigma-Aldrich (Stockholm, Sweden). L( +)-Ascorbic acid (99.0–100.5%) was from VWR chemicals (Stockholm, Sweden). Water (MQ H2O) was purified in a Millipore Synergy® 185 (Bedford, MA, USA) to a resistivity of 18.2 MΩ·cm at 25 °C. DEAE Affi-Gel® Blue Gel (DEAE) used for IgG extraction was obtained from Bio-RAD, Hercules, USA. Pierce® C18 Tips, 100 µL bed size, were from Thermo Fisher Scientific (Rockford, USA). Kinesis Tubing PEEK (TM) natural 1/32 inch × 0.015 inch connecting syringe and microchip was purchased from Fisher Scientific (Stockholm, Sweden). MALDI matrices 2,5-dihydroxybenzoic acid (DHB) and α-cyano-4-hydroxycinnamic acid (HCCA) and MALDI plate were obtained from Bruker Daltonics (Bremen, Germany).
+ Open protocol
+ Expand
3

Plasma Treatment for UV-Cured POSS-Based Coatings

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

Coating solutions made from the blend of MA0736 POSS™ molecules (available from Hybrid Plastics Inc., Hattiesburg, Miss.), CN991 (aliphatic urethane acrylate from Sartomer, Exton, Pa.), CN2303 (alkoxylated multifunctional acrylate oligomer from Sartomer), tetrahyhydrofurfuryl alcohol (TFHA) and Lucirin™ TPO-L (photoinitiator, available from BASF) were applied to primed PET film and cured by UV source. The coated film was then treated with oxygen plasma for 90 seconds. The % reflection was measured and reported with the formulations and treatment conditions in Table 4.

TABLE 4
Reflection results of plasma treated samples of Example 3
Formulation (wt %)O2 plasma
CN991/CN2303treatment timeAverage % R
SampleCN991(70:30)THFAMA0736TPO-L(seconds)(400-800 nm)
160881002903.37
170871012902.89
180851032902.65
190831052902.03
200811072901.44
2107810102901.01
2207310152900.9
2306810202900.73

+ Open protocol
+ Expand
4

Synthesis and Characterization of Polymeric Biomaterials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Trimethylene carbonate (1,3-dioxan-2-one, TMC) was obtained from Foryou Medical, China. Stannous octoate (tin 2-ethylhexanoate, SnOct 2 ), trimethylolpropane (TMP), trimethylamine, methacrylic anhydride, hydroquinone, methanol absolute, anhydrous dichloromethane and propylene carbonate were purchased from Sigma-Aldrich, Germany. Lucirin TPO-L (ethyl 2,4,6-trimethylbenzoylphenyl phosphinate) was provided by BASF, Germany. Orasol Orange G was obtained from Ciba Specialty Chemicals, Switzerland. Reagents and solvents were of analytical grade and used as received.
+ Open protocol
+ Expand
5

OSTE Devices Surface Modification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The fabricated OSTE devices prepared for capillary filling experiments was rendered hydrophilic by UV grafting of HEMA. A solution of 5% hydroxyethylmethacrylate (HEMA) (Sigma-Aldrich, USA), 0.1% Lucirin TPO-L (BASF Corp., USA), and 0.1% benzophenone (BP) (Sigma-Aldrich, USA) in isopropyl alcohol (IPA) (SunChem AB, Sweden) was prepared. A glass slide was placed above the device, with 150 μm spacing between the top surface of the interlocked pillar array and the glass slide, where the solution was injected. Collimated UV-light was illuminated onto the solution and the pillar array through the glass slide for 300 seconds. After the exposure, the pillar array was rinsed with pure IPA, soaked and incubated with pure IPA for 300 seconds, and dried at room temperature.
+ Open protocol
+ Expand
6

Glycan Analysis with Enzyme-Linked Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents Pentaerythritol-tetrakisIJ3-mercaptopropionate) ("tetrathiol"), triallyl-1,3,5-triazine-2,4,6IJ1H,3H,5H)-trione ("triallyl"), 2-(boc amino)ethanethiol, L-ascorbic acid (ASA), galactose-oxidase from Dactylium dendroides [50 U ml -1 ], horseradish peroxidase (HRP, lyophilized powder, 150 U mg -1 ), PNGase F, ninhydrin, D-galactose, D-IJ+)-glucose, ribonuclease B (RNase B from bovine pancreas (50 Kunitz units per mg protein)), 10acetyl-3,7-dihydroxyphenoxazine (ADHP), Tween 20 and 5,5′-dithiobisIJ2-nitrobenzoic acid) (DTNB) were obtained from Sigma Aldrich (Brøndby, DK). Lucirin TPO-L (ethyl-2, 4, 6-trimethylbenzoylphenyl phosphinate) was obtained from BASF (Hardmatt, CH). Sylgard 184 -polyIJdimethylsiloxane) (PDMS) elastomer kit was obtained from Dow Corning (Midland, MI, USA). Hypermer B246 and Span 80 surfactants were obtained from Croda International Plc (Snaith, UK)
+ Open protocol
+ Expand
7

Polymer Fabrication for Cell Culture

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methyl methacrylate (MMA), Butyl methacrylate (BMA), Poly(ethylene glycol) dimethacrylate (PEGDA Mw = 550) were obtained from Sigma–Aldrich and used without further purification. Technical grade isopropanol and acetone were obtained from Biosolve (The Netherlands) and they were used as received. Lucirin TPO-L (ethyl-2,4,6-trimethylbenzoylphenylphosphinate) was kindly provided by BASF, Germany. D-MEM, Fetal bovine serum (FBS) and Glutamax was provided by Gibco, USA. Penicilin and streptomycin was provided by EuroClone S.p.a., Italy. C2C12 muscle myoblast cell line was supplied from ATCC® leading biological standards. Human osteoblasts were extracted from human tibia gently donated from Villa Betania Hospital.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists