Slide a lyzer tm 2000 mwco dialysis cassettes

Manufactured by Thermo Fisher Scientific

The Slide-A-Lyzer TM 2000 MWCO dialysis cassettes are a laboratory equipment product designed for dialysis applications. They have a molecular weight cutoff of 2000 Da and are intended for sample preparation and purification processes.

Automatically generated - may contain errors

2 protocols using slide a lyzer tm 2000 mwco dialysis cassettes

1

Plectasin Dialysis and Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
If not stated otherwise, all plectasin samples were dialyzed into the desired condition using Slide-A-Lyzer TM 2000 MWCO dialysis cassettes (Thermo Fisher) with a buffer exchange after 2 and 4 hours and then continued overnight, ensuring a 200-fold dilution each step. The protein concentration after dialysis was measured using a NanoDrop™ 8000 Spectrophotometer (ThermoFisher). If not stated otherwise, all measurements were performed at a protein concentration of 2 mg/ml (455µM), obtained by dilution into the final condition. Filtration of the sample and buffer was performed using Luer-Lok TM syringes (BD) and 0.22µm Millex®-GV filter (Merck) or 0.02µm Whatman Anotop TM 10 filter (GE Healthcare Life Science). The pH reported was measured on the dialysis buffer if not otherwise stated.
+ Open protocol
+ Expand
2

Plectasin Dialysis and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
If not stated otherwise, all plectasin samples were dialyzed into the desired condition using Slide-A-LyzerTM 2000 MWCO dialysis cassettes (Thermo Fisher) with a buffer exchange after 2 and 4 h and then continued overnight, ensuring a dilution of at least 200 times in each step. The concentration of plectasin wildtype stock solution was c = 39 mg/mL (8.9 mM) and of PPI42 c = 37 mg/mL (8.4 mM). If not gelled, the protein concentration after dialysis was measured using a NanoDrop™ 8000 Spectrophotometer. The pH reported was the measured pH of the dialysis buffer, if not stated otherwise. Different buffers were chosen to ensure sufficient buffer capacity at different pH values. For the lower pH range (pH 3.5–5.5) sodium acetate buffer was chosen, if not stated otherwise. For the neutral pH range (pH 5–7.5) phosphate buffer was chosen, if not stated otherwise.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!