The largest database of trusted experimental protocols

Dee6500 2 cat

Manufactured by Demeditec Diagnostics
Sourced in Germany

The DEE6500 2-CAT is a laboratory equipment product from Demeditec Diagnostics. It is designed for the quantitative determination of catecholamines in various biological samples.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using dee6500 2 cat

1

Arterial and Venous Blood Sampling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Arterial and femoral venous blood samples (1 ml each) were drawn into preheparinized syringes and analyzed immediately for blood gas variables, hemoglobin, electrolytes, lactate, and glucose (ABL 800 FLEX; Radiometer, Copenhagen, Denmark) with values corrected to blood temperatures measured simultaneously from the site of sampling in each vessel and the analyzer calibrated at regular intervals in accordance with manufacturer guidelines. Additional arterial and femoral venous blood samples from both legs were collected in 2-ml syringes and transferred to EDTA tubes, centrifuged, and separated. Plasma adrenaline and noradrenaline were subsequently determined using an enzyme-linked immunoassay kit (DEE6500 2-CAT; Demeditec Diagnostics GmbH, Kiel, Germany).
+ Open protocol
+ Expand
2

Arterial and Venous Blood Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Arterial and jugular venous blood samples were drawn into pre-heparinised syringes and analysed immediately for blood gas variables (ABL 800 FLEX, Radiometer, Copenhagen, Denmark) corrected for blood temperature in the internal jugular vein. The analyser was calibrated at regular intervals in accordance with manufacturer guidelines. Additional arterial and jugular venous blood was collected in 2 ml syringes and transferred to EDTA tubes, centrifuged and separated. Plasma adrenaline and noradrenaline were subsequently determined using an enzyme immunoassay kit (DEE6500 2-CAT, Demeditec Diagnostics GmbH, Kiel, Germany). Blood samples were also collected directly in stop solution (Gorman et al. 2003 (link); Kalsi & González-Alonso, 2012 (link)). Plasma ATP was then determined using the luciferin–luciferase technique by a luminometer with three automatic injectors (Orion Microplate Luminometer, Bethold Detection System GmbH, Pforzheim, Germany).
+ Open protocol
+ Expand
3

Blood Gas and Catecholamine Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Arterial and jugular venous blood samples were drawn into preheparinized syringes and analyzed immediately for blood gas variables (ABL 800 FLEX, Radiometer, Copenhagen, Denmark), corrected for blood temperature in the internal jugular vein. The analyzer was calibrated at regular intervals in accordance with manufacturer guidelines. Additional arterial and jugular venous blood were collected in 2-ml syringes, transferred to EDTA tubes, centrifuged, and separated. Plasma epinephrine and norepinephrine (NE) were subsequently determined using an enzyme-linked immunoassay kit (DEE6500 2-CAT, Demeditec Diagnostics).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!