The G1321A FD is a fluorescence detector designed for liquid chromatography (LC) applications. It is capable of detecting fluorescent compounds in liquid samples.

Automatically generated - may contain errors

4 protocols using g1321a fd

1

HPLC Fluorescence Detection of OPA Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC was performed using Agilent 1200 HPLC with G1321A FD, and Eclipse AAA column (4.6×150 mm, 5 µm) with an excitation wavelength (λex) of 340 nm and an emission wavelength (λem) of 455 nm, and a column temperature of 40°C. The derivative liquid was compounded as follows: 5 mg o-Phthalaldehyde was dissolved in 120 µL dehydrated ethanol, and then added to 1 mL borate buffer (0.2 mol/L, pH 9.2) and 10 µL β-mercaptoethanol. Mobile phase A consisted of sodium borate buffer, methanol, and tetrahydrofuran (in a ratio of 400:95:5), and mobile phase B consisted of sodium acetate buffer solution (pH 7.2) and methanol (in a ratio of 120:380). The gradient elution procedure was 0–10 minutes, B (0%–63%), 10–12 minutes, B (63%), 12–17 minutes, B (100%), 17–18 minutes, B (100%–0%), and 18–21 minutes, B (0%). The flow rate was 0.8 mL min−1.
+ Open protocol
+ Expand
2

HPLC Separation and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC was performed using Agilent 1200 HPLC with G 1321 A FD and Eclipse AAA columns (4.6× 150 mm, 5 m) and column temperature of 40°C. Mobile phase A (formic acid: water = 1: 1000) and mobile phase B (acetonitrile). Gradient elution procedure is 0-70 minutes, B (0%-63%), 0-20 minutes, B (63%), 20-40 minutes, B (100%), 50 minutes, B (100%-0%), and 50-70 minutes, B (0%). The flow rate was 0.4 ml min−1.
+ Open protocol
+ Expand
3

HPLC Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC was performed using Agilent 1200 HPLC with G1321A FD and Eclipse AAA column (4.6 × 150 mm, 5 μm) and a column temperature of 40°C: mobile phase A (formic acid : water = 1 : 1000) and mobile phase B (acetonitrile). The gradient elution procedure was 0–13 minutes, B (0%–63%), 0–8 minutes, B (63%), 9-10 minutes, B (100%), 11 minutes, B (100%–0%), and 12-13 minutes, B (0%). The flow rate was 0.4 ml min−1.
+ Open protocol
+ Expand
4

HPLC Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC was performed using Agilent 1200 HPLC with G1321A FD, Eclipse AAA column (4.6×150 mm, 5 μm), and a column temperature of 40°C. Mobile phase A (formic acid: water =1:1000) and mobile phase B (acetonitrile). The gradient elution procedure was 0–13 minutes, B (0%–63%), 0–5 minutes, B (63%), 5-8 minutes, B (100%), 9 minutes, B (100%–0%), and 10-13 minutes, B (0%). The flow rate was 0.4 mL min−1.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!