The largest database of trusted experimental protocols

Triple tof 5600 1

Manufactured by AB Sciex
Sourced in United States

The Triple TOF 5600-1 is a hybrid quadrupole time-of-flight (QTOF) mass spectrometer designed for high-resolution, accurate-mass (HRAM) analysis. It features a triple quadrupole configuration coupled with a time-of-flight mass analyzer, enabling both quantitative and qualitative analysis capabilities.

Automatically generated - may contain errors

2 protocols using triple tof 5600 1

1

HPLC-QTOF/MS Protocol for Compound Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Shimadzu LC30-AD HPLC system (Shimadzu, Kyoto, Japan) combined with a quadrupole time-of-flight mass spectrometer (Triple TOF 5600-1, AB SCIEX, Redwood City, CA, USA) was used. An Agilent Zorbax SB-C18 column (4.6 mm × 50 mm, 1.8 μm, Agilent Technologies, USA) with a column temperature maintained at 30 °C was employed. The mobile phase consisted of 0.1% formic acid (A) and acetonitrile (B), using a gradient elution of 10–20% B at 0–2 min, 20–22% B at 2–9 min, 22–40% B at 9–16 min, 40–70% B at 16–17 min, 70–100% B at 17–18 min, and 100% B at 18–19 min with an equilibrium for 4 min. The flow rate was set at 0.4 mL min−1 with an injection volume of 2 μL.
MS detection was performed using QTOF/MS in negative ionization mode with a DuoSpray ion source. The QTOF/MS was calibrated in high sensitivity mode and the automated calibration device system (CDS) was set to perform an external calibration every four samples using a calibration solution. The source parameters were optimized: collision voltage (CE), 50 eV; ion spray voltage floating (ISVF), 4500 V; temperature, 500 °C; nebulizing gas (GS1), 60 psi; heater gas (GS2), 60 psi; curtain gas, 35 psi. The MS was operated in full-scan TOF/MS (100–2000 amu) and MS/MS mode (100–2000 amu) through data-independent acquisition (DIA) in a single-run analysis.16 (link)
+ Open protocol
+ Expand
2

Mass Spectrometry Analysis of Biological Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mass analysis was performed on Q‐TOF analyzer in TripleTOF 5600‐1 (AB Sciex, USA) in positive ion and negative ion mode, using the following parameters: Ion source voltage, 5500 V(positive ion) and 4500 V (negative ion); source temperature, 550°C; DP: 60 V(positive ion) and −60 V (negative ion); CE: 10 eV(positive ion) and −10 eV (negative ion); CES: 15 eV; GS1and GS2 60 psi; CUR: 35 psi. Primary mass spectrometry parent ion scan range of m/z 50–1700, IDA set the 12 highest peaks with response values above 100 cps for secondary mass spectrometry, daughter ion scan range of m/z 25–1200, dynamic background subtraction (DBS) enabled.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!