The largest database of trusted experimental protocols

Rat svcam 1

Manufactured by MyBioSource
Sourced in United States

The Rat sVCAM-1 is a laboratory equipment used for the detection and quantification of soluble vascular cell adhesion molecule-1 (sVCAM-1) in rat samples. sVCAM-1 is an important biomarker associated with various physiological and pathological conditions. The equipment utilizes an enzyme-linked immunosorbent assay (ELISA) technique to measure the concentration of sVCAM-1 in the given samples.

Automatically generated - may contain errors

2 protocols using rat svcam 1

1

Measurement of Biomarkers in Diabetic Rats

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood glucose was measured using an Accu-Chek™ Performa glucometer (Roche, Basel, Switzerland), and urine volume was measured gravimetrically. The concentrations of rat sVCAM-1 (MyBioSource, San Diego, CA, USA, Cat. No. MBS762680), rat sICAM-1 (MyBioSource, San Diego, CA, USA, Cat. No. MBS266128), rat albumin (AssayMax, St. Charles, MO, USA, Cat. No. ERA3201-1), rat VEGF-A (Thermo Scientific, Waltham, MA, USA, Cat. No. ERVEGFA), rat thrombin–antithrombin (TAT) complex (Novus Biologicals, Easter Ave Centennial, CO, USA, Cat. No. NBP2-68132) and nucleosomes (Roche, Basel, Switzerland, Cat. No 11 774 425 001) were measured using immunoenzymatic assays. The enzymatic method was used to measure creatinine (Wiener lab., Rosario, Santa Fe, Argentina) and urea (BioSystems, Barcelona, Spain) concentrations. Total protein was measured with a biuret reagent.
+ Open protocol
+ Expand
2

Biomarkers of Vascular Inflammation in Rats

Check if the same lab product or an alternative is used in the 5 most similar protocols
The blood glucose was determined with an Accu-Chek Performa glucometer (Roche, Basel, Switzerland), and the urine volume was determined gravimetrically. Immunoenzymatic assays were used to measure the concentration of rat sVCAM-1 (MyBioSource, San Diego, CA, USA, Cat. No. MBS762680) and rat sICAM-1 (MyBioSource, San Diego, CA, USA, Cat. No. MBS266128). The creatinine (Wiener lab., Rosario, Santa Fe, Argentina) and urea (BioSystems, Barcelona, Spain) concentrations were measured by the enzymatic method.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!