The largest database of trusted experimental protocols

Pc04n

Manufactured by Bangs Laboratories

The PC04N is a laboratory equipment product from Bangs Laboratories. It is designed to perform core functions for laboratory applications. The detailed specifications and intended use are not available for this product.

Automatically generated - may contain errors

2 protocols using pc04n

1

Avidin-labeled Low Mobility Beads

Check if the same lab product or an alternative is used in the 5 most similar protocols
Low electrophoretic mobility avidin-labeled beads were made from 1.5 µm diameter carboxypolystyrene beads (PC04N, Bangs Laboratories, Fishers, IN). Fifty µL of beads were washed 2× in 200 mM 2-(N-morpholino)ethanesulfonic acid (MES, pH 6) with 0.1% sodium dodecyl sulfate (SDS) and resuspended in 500 µL of MES buffer and mixed with 500 µL of 10 mg/ml EDC (Sigma-Aldrich, St. Louis, MO) to activate the carboxy groups. After 15 minutes, beads were washed with 200 mM sodium phosphate buffer (pH 7.5) with 0.1% SDS. The washed beads were resuspended in 150 µL and reacted with 1 µM avidin (Sigma-Aldrich, St. Louis, MO) and 25 mM 1 kDa amino-PEG (#26116, Pierce, Rockford, IL) for 3 hours at room temperature. Beads were washed and resuspended in 10 mM Tris (pH 8) with 50 mM NaCl and stored at 4 °C. Where indicated, 1 µm diameter streptavidin coated beads (CP01N, Bangs Laboratories, Fischers, IN) having high electrophoretic mobility were used in place of the custom beads.
+ Open protocol
+ Expand
2

Surface-Functionalized Polystyrene Microbeads

Check if the same lab product or an alternative is used in the 5 most similar protocols
Polystyrene microbeads functionalized with surface carboxyl groups (diameter = 0.99 μm (μP1), 1.04 μm (μP2), and 0.20 μm (μP3)) were obtained from Bangs Laboratories, Inc. (Fishers, IN); FC04N, PC04N, and PC02N, respectively. BODIPY disulfonate fluorophore (BODIPY2–) was obtained from Molecular Probes (Eugene, OR). Pluronic F108 was purchased from BASF (Florham Park, NJ). Tris–HCl buffer solution was prepared by dissolving reagent grade Trizma base (Sigma-Aldrich, St. Louis, MO) in deionized water (18.0 MΩ cm, Milli-Q Gradient System, MilliporeSigma, Burlington, MA) and then adjusting the solution pH to 8.1 using 1.0 M HCl (Fisher Scientific, Hampton, NH). Microfluidic channels were fabricated using poly(dimethylsiloxane) (PDMS) prepared from a silicone elastomer kit (Sylgard 184, Dow, Midland, MI).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!