The largest database of trusted experimental protocols

1200 series binary pump g1312b

Manufactured by Phenomenex
Sourced in United States

The 1200 series binary pump (G1312B) is a high-performance liquid chromatography (HPLC) pump that delivers precise and reliable solvent flow. It features two independent solvent channels and is capable of binary gradient formation. The pump operates at a maximum pressure of 600 bar and a flow rate range of 0.001 to 10 mL/min.

Automatically generated - may contain errors

2 protocols using 1200 series binary pump g1312b

1

Melting Point and NMR Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points were determined on a capillary tube melting point apparatus equipped with a digital thermometer. NMR spectra were recorded in DMSO-d6 on a Bruker NMR spectrometer operating at 500 MHz for 1H (with TMS as an internal standard) and 125 MHz for 13C. were performed on reverse phase gradient using Agilent (Santa Clara, CA, USA) 1200 series binary pump (G1312B), waters XTerra MS C18 (3.5 mm; 2.1–150 mm) þ Phenomenex C18 security guard column (2–4 mm) using 0.2% acetic acid in H2O/methanol as mobile phases; wavelength ¼ 254 nm; and mass spectrometry was done with 6220 Agilent (Santa Clara, CA, USA) TOF in electrospray ionization (ESI) mode with a positive and negative method in both Profile and Centroid mode. HPLC studies were done with 6120 Agilent (quadrupole LC/MS) [29 (link)].
+ Open protocol
+ Expand
2

Compound Purification and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
All materials were purchased from commercial suppliers and used with no extra purification. The final compounds' purities were elucidated by tandem mass spectrometry (LC/MS) using a gradient elution system (acetonitrile/water 5/95/95/5, 5 min, 0.05% formic acid) on Ascentis Express Peptide C18 column, and UV detection (254 nm). The final compounds' purities were 95% or greater. A Bruker NMR 400 MHz Avance III spectrometer operating at 100 MHz for 13C NMR and 400 MHz for 1H NMR was utilised for NMR spectra recording. Chemical shifts are given relative to tetramethylsilane (TMS) in part per million (ppm), and coupling constants J are given in Hertz. HPLC-HRMS analyses were carried out using Agilent (Santa Clara, CA) 1200 series binary pump (G1312B), and columns waters XTerra MS C18 (3.5 um; 2.1 × 150 mm) + Phenomenex C18 security guard column (2 × 4 mm) on gradient elution mobile phase using 0.2% acetic acid in H2O/methanol; wavelength = 254 nm. Elemental analyses were established at Microanalytical Centre, Faculty of Science, Cairo University, Egypt using Manual Elemental Analyser Heraeus (Germany) and Automatic Elemental Analyser CHN Model 2400 Perkin Elmer (USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!