The largest database of trusted experimental protocols

Tecnai 12 transmission

Manufactured by Ametek

The Tecnai 12 is a transmission electron microscope (TEM) designed for materials science and life science applications. It operates at an accelerating voltage of 120 kV and provides high-resolution imaging of samples. The instrument is capable of analyzing the structure and composition of materials at the nanoscale level.

Automatically generated - may contain errors

2 protocols using tecnai 12 transmission

1

Transmission Electron Microscopy of EVs

Check if the same lab product or an alternative is used in the 5 most similar protocols
EV samples were adsorbed to glow‐discharged carbon‐coated 400‐mesh copper grids for 3 min and then stained with 2% (weight/volume) uranyl acetate in water, rinsed briefly with water, and air‐dried. The grids were visualized in a FEI Tecnai 12 transmission EM at 80 kV. Images were captured on a Gatan Orius CCD camera with Gatan Digital Micrograph software.
+ Open protocol
+ Expand
2

Negative Staining and Cryo-EM of Supercomplexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
For negative staining, purified SCs were diluted to 0.01–0.05 mg/mL concentrations in TBS (50 mM Tris-HCl, pH 7.4, 150 mM NaCl, 0.01% DDM, and 1 mM AEBSF) buffer, 5 μL applied to glow-discharged (20 s, 25 mA, Pelco easiGlow) carbon-coated Cu grids (CF300-CU, EMS), incubated for 1 min, and stained with 2% uranyl acetate. Grids were imaged on FEI Tecnai 12 transmission electron microscope operating at 120 kV, with a CCD camera (Gatan BM-Ultrascan).
For cryo-EM, the tripartite SC was used as purified, whereas the purified bipartite SC was mixed with a 5-fold molar excess of purified cyt cy75 (link). In all, 2.5 μL of the mixture, containing 3–5 mg/mL proteins, were applied to CFlat holey carbon grids (1.2/1.3–400 mesh or 2/2–300 mesh) (EMS), which were glow discharged (2 min, 25 mA, Pelco easiGlow) before sample application. Grids were blotted for 9 s at force 0 (CFlat-1.2/1.3) or for 3 s at force −5 (CFlat-2/2) and flash-frozen in liquid ethane cooled with liquid nitrogen using FEI Vitrobot Mark IV (25 °C, 100% humidity). Plunge freezing conditions were optimized using FEI Tecnai TF20 TEM operating at 200 kV, equipped with an FEI Falcon II camera.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!