The largest database of trusted experimental protocols

Lactose standard

Manufactured by Merck Group
Sourced in United States

The Lactose standard is a laboratory product that provides a known concentration of the disaccharide lactose for use in analytical methods. It serves as a reference material to ensure the accuracy and precision of lactose measurements.

Automatically generated - may contain errors

3 protocols using lactose standard

1

Determination of Lactose in Breast Milk

Check if the same lab product or an alternative is used in the 5 most similar protocols
A high-performance liquid chromatography (HPLC) method was used to determine lactose concentration in breast milk (AOAC [Association of Official Analytical Collaboration] Official Method 980.13) [14 ]. Lactose standard was obtained from Sigma-Aldrich Chemical Co. (St. Louis, MO, USA). Standard solution of lactose at a concentration range between 0.005% and 1% was prepared and used to create the calibration curve. Prior to injection, all standards were filtered into individual 2 mL vials through 0.45 µm filters to remove any small particles.
+ Open protocol
+ Expand
2

Quantification of Organic Acids and Lactose

Check if the same lab product or an alternative is used in the 5 most similar protocols
Organic acids and lactose were extracted using a method modified from Upreti et al. (2006) . Permeates were analyzed at 10% solids. One hundred microliters of each sample was extracted in 900 μL of 0.013 N H 2 SO 4 (Sigma Aldrich, St. Louis, MO), vortexed, and centrifuged at 8,000 × g at room temperature (21°C) for 5 min. The top layer was removed and filtered using 0.45-μm nylon syringe filters (VWR International, West Chester, PA). Twenty microliters of each sample was injected on the HPLC (Waters 1525 Binary Pump, Waters, Milford, MA) using an autosampler (Waters 2707 Autosampler) onto the column (0.8 mL/min, 300 × 7.8 ion exclusion, 55°C; Bio-Rad Labs, Richmond, CA). Each replicate of each permeate was injected in duplicate. The temperature of the injector was 4°C and a photodiode array detector (Waters 2998) was used for organic acids and a refractive index detector (Waters 2414 Refractive Index Detector, 30°C) was used for lactose. The maxima used for organic acid calculation was 254 and 285 nm due to citric and orotic acids coeluting at 254 nm. Citric acid was not detected at 285 nm. A standard curve was created for each organic acid and lactose. Organic acid standards were obtained from Thermo Fisher Scientific Inc. (Pittsburgh, PA) and lactose standard was obtained from Sigma Aldrich.
+ Open protocol
+ Expand
3

Lactose and Lactulose Analysis by HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
Acetonitrile HPLC and LC/MS grade, water LC/MS grade, Formic acid LC/MS grade, Lactose standard, Lactulose standard, Ethanol HPLC grade and D-Lactose-1-13 C monohydrate, Potassium hexacyanoferrate (II) trihydrate, zinc sulphate, trichloroacetic acid were bought from Sigma Aldrich (US-MO).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!