Nylon syringe filter

Manufactured by PerkinElmer
Sourced in China

The Nylon syringe filter is a laboratory equipment designed to filter liquids. It features a nylon membrane that removes particulates from the sample, ensuring a clear and contaminant-free solution for further analysis or processing.

Automatically generated - may contain errors

2 protocols using nylon syringe filter

1

Quantitative Analysis of Pesticides using LC-MS/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols

LC System—QSight® LX-50 LC (PerkinElmer, Shelton, CT).

MS system——QSight™ 420 MS/MS detector with ESI and APCI source with HSID interface and Simplicity 3Q™ software platform (PerkinElmer, Shelton, CT).

LC Column—Quasar SP Pesticides C18, 100 mm long, 4.6 mm ID, 2.7 μm particle size, and particle is superficially porous (PerkinElmer, Shelton, CT).

Mixer—analog vortex mixer (VWR, Radnor, PA).

Centrifuge—Eppendorf centrifuge 5430 (Eppendorf Co. Ltd).

Polypropylene centrifuge tubes—15 mL and 50 mL (PerkinElmer, Shelton CT).

Glass volumetric flasks—50 mL (VWR, Radnor, PA).

Syringes—3-mL plastic syringes with Luer lock (Becton Dickinson, Fingerlakes, NJ).

Filter—Nylon syringe filter, diameter 30 mm, 0.22 μm pore size (PerkinElmer, Shelton, CT).

LC vials—2-mL amber glass (PerkinElmer, Shelton, CT).

+ Open protocol
+ Expand
2

Quantifying Epicatechin in Freeze-Dried Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Epicatechin was determined following the method used by Guetsky et al. (2005) , with some modifications. Freeze-dried samples (20 mg) were homogenised in methanol: water (1:1; v/v) solution. Thereafter, the Eppendorf tubes were centrifuged for 10 min at 14 000 x g. The supernatant was transferred to the new tubes, and subsequently filtered through a 0.45 μm membrane (Nylon syringe filter, PerkinElmer™, China) prior to injection. The analyses were carried out using a Flexar™ HPLC system (PerkinElmer, USA) consisting of a Flexar Isocratic LC Pump Platform and a variable wavelength Flexar UV/ ViS LC detector. Separation was done on an Analytical C18 column (100 x 4.6 mm; 5 μm) at 25 °C, using water/methanol (25:75 v/v) as a mobile phase, with a flow rate of 1 ml min -1 . Chromatographic peak of the epicatechin was identified by comparing the retention time with that of the pure epicatechin (HPLC grade) standard at 320 nm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!