The largest database of trusted experimental protocols

2 protocols using hydroxymethyledot

1

Fluorinated EDOT Polymer Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
As described in the Supporting Information, fluorinated 3,4-ethylenedioxythiophene with a
perfluorooctanyl side chain (EDOTF) was custom-synthesized from hydroxymethyl
EDOT (95%) and pentadecafluorooctanoyl chloride (97%) obtained from
Sigma-Aldrich. High-molecular-weight PVC (HMW PVC), bis(2-ethylhexyl)
sebacate (DOS), potassium ionophore I (valinomycin), and tetrahydrofuran
(THF), all Selectophore grade, and anhydrous acetonitrile (ACN; 99.5%)
were purchased from Sigma-Aldrich. KTFAB (97%; Figure S-1) was obtained from Alfa Aesar, and KCl (99.999%,
Suprapur grade) was received from Merck Millipore. All aqueous solutions
were prepared from deionized water (DIW) with a resistivity of 18.2
MΩ cm (ELGA).
+ Open protocol
+ Expand
2

Functionalized EDOT-based Conductive Polymers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Hydroxymethyl EDOT (EDOT-OH, 95%), sodium hydride (NaH, 60% dispersion in mineral oil), trityl chloride (97%), magnesium sulfate (MgSO4), potassium carbonate (K2CO3), triphenylphosphine (PPh3), Amberlite IR-120 resin, sodium methoxide (NaOMe), iron(III) p-toluenesulfonate hexahydrate (technical grade), imidazole (IM, 99%), dimethyl sulfoxide (DMSO), (3-glycidoxypropyl)trimethoxysilane (GOPS, ≥98%), hydrogen tetrachloroaurate(III) hydrate (HAuCl4), trisodium citrate dihydrate (TSC, 99%), DA, AA, UA, and PC were purchased from Sigma–Aldrich. The aqueous PEDOT:PSS solution (Clevios PH1000, PEDOT:PSS ratio = 1:2.5) was purchased from Heraeus with a solid concentration 1.0–1.3 wt%. Tetrahydrofuran (THF), ethyl acetate (EA), hexane, acetone, carbon tetrabromide (CBr4), potassium thioacetate (KSAc), hydrochloric acid (HCl, 37%), and nitric acid (HNO3, 70%) were purchased from Acros Organics. All materials and reagents were used as received without further purification. The aqueous solutions were prepared with deionized (DI) water from a Millipore Milli-Q water treatment system (18.2 MΩ cm−1).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?