The largest database of trusted experimental protocols

Silica gel 60 m

Manufactured by Merck Group
Sourced in Germany

Silica Gel 60 M is a type of porous silica-based material used in various laboratory applications. It is a fine, granular substance that possesses a high surface area and the ability to adsorb moisture and other substances. The core function of Silica Gel 60 M is to serve as a desiccant, absorbing and trapping water and other polar molecules in order to maintain dry conditions in enclosed environments.

Automatically generated - may contain errors

6 protocols using silica gel 60 m

1

Chlorination of Emodin Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 114 mg of emodin (0.42 mmol, 1 eq) was dissolved in 5 ml of tetrahydrofuran (THF) and treated with 169 mg (1.26 mmol, 3 eq) of N-chlorosuccinimide. The reaction mixture was stirred in RT for 18 h, then evaporated with silica gel (Silica Gel 60 M (0.040-0.063 mm, E. Merck) and purified by column chromatography using 5% methanol in chloroform for monochloroemodins and 20% methanol in chloroform for 5,7-dichloroemodin33 (link). The following yields were obtained: 19.8 mg (15.5%) for 7-chloroemodin and 12.6 mg (8.8%) of 5,7-dichloroemodin.
+ Open protocol
+ Expand
2

Organic Synthesis Characterization Methods

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercially available chemicals were of reagent grade and used as received. The reactions were monitored by thin layer chromatography (TLC) analysis using silica gel plates (Kieselgel 60F254, E. Merck). Column chromatography was performed on Silica Gel 60 M (0.040 × 0.063 mm, E. Merck). Optical rotations were measured with a PerkinElmer 341 polarimeter in appropriate solvent, at the indicated temperature (20 °C) and at 589 nm sodium line, in a 1 dm cell. Concentrations are given in g/100 mL. The 1H and 13C NMR spectra were recorded on a Varian InovaUnity 400 spectrometer (400 MHz) in (d4) methanol, CDCl3, shift values in parts per million relative to SiMe4 as internal reference. High Resolution Mass spectra were performed on a Bruker maXis mass spectrometer by the “Federation de Recherche” ICOA/CBM (FR2708) platform.
+ Open protocol
+ Expand
3

Synthesis and Characterization of Novel Benzimidazole Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents and solvents were used as purchased, without further purification. The reactions were moni-Yeşilçayır et al.: Novel Benzimidazole-Based Compounds ... tored by thin-layer chromatography (TLC) analysis using silica gel plates (Kieselgel 60F254, E. Merck). Column chromatography was performed on Silica Gel 60 M (0.040-0.063 mm, E. Merck). Melting points were determined on a Büchi B540 capillary melting point apparatus and are uncorrected. The 1 H and 13 C NMR spectra were recorded on a Varian 400 MHz and Bruker 500 MHz FT spectrometer in DMSO-d 6 , shift values are given in parts per million relative to tetramethylsilane as internal reference and coupling constants (J) are reported in Hertz. Mass spectra were taken on a Waters Micromass ZQ connected with Waters Alliance HPLC, using ESI+ method, with the C-18 column. Elemental analyses were performed by Leco CHNS-932 analyzer.
+ Open protocol
+ Expand
4

Silica Gel Column Chromatography

Check if the same lab product or an alternative is used in the 5 most similar protocols
Column chromatography was performed on silica gel 60 M (0.040 to 0.063 mm; Macherey-Nagel GmbH & Co.), with a maximum pressure of 1.6 to 2.0 bar. A preparative chromatography system (Büchi Labortechnik GmbH) with a Büchi Control Unit C-620, a UV detector Büchi UV photometer C-635, a Büchi fraction collector C-660, and two C-605 pump modules was used to adjust the solvent mixtures. Mixtures of cyclohexane and ethyl acetate were used as eluents. silica gel 60 M on aluminum sheets (F254, Merck Millipore) was used for thin-layer chromatography.
+ Open protocol
+ Expand
5

Synthesis and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercially available chemicals were of reagent grade and used as received. The reaction progress was monitored using LR-ESI-MS spectra and thin layer chromatography (TLC) using silica gel plates (Kieselgel 60F254, E. Merck, Darmstadt, Germany). Column chromatography used for purification and isolation of compounds was performed on silica gel 60 M (0.040–0.063 mm, E. Merck, Darmstadt, Germany). Melting points were measured using Büchi (New Castle, DE, USA) Melting Point B-540 apparatus. All 1H and 13C NMR spectra were recorded on a Bruker Avance III spectrometer operating at 500.13 (1H) and 125.77 (13C) MHz and equipped with a 5 mm probe head with Z-gradient coils. The experiments were performed using pulse programs from standard Bruker library for samples dissolved in CDCl3, DMSO-d6, or MeOH-d4. In each case, spectra were calibrated at residual solvent resonances. High resolution mass spectra were performed by the Laboratory of Mass Spectrometry, Institute of Biochemistry and Biophysics PAS, on a LTQ Orbitrap Velos instrument, Thermo Scientific (Waltham, MA, USA). Synthetic procedures, physicochemical properties, and spectra related to synthesized compounds are included in the supplementary file.
+ Open protocol
+ Expand
6

Synthesis and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Commercially available chemicals were of reagent grade and used as received. Purification of the compounds was performed by column chromatography on silica gel 60 M (0.040–0.063 mm, E. Merck, Darmstadt, Germany). Thin layer chromatography (TLC), using silica gel plates (Kieselgel 60F254, E. Merck), was used to monitor reaction progress. A B-540 Melting Point apparatus (Büchi, New Castle, DE, USA) was used to measure melting points. The 1H-NMR and 13C-NMR spectra, in DMSO-d6 and CDCl3, were recorded at the Department of Chemistry, University of Warsaw, using an AVANCE III HD 300 MHz spectrometer (Bruker, Billerica, MA, USA); shift values in parts per million are relative to the SiMe4 internal reference. The resonance assignments were based on peak multiplicity and peak integration of recorded spectra, Multiplets were assigned as bs (broad singlet), s (singlet), d (doublet), t (triplet) dd (doublet of doublet), ddd (doublet of doublet of doublet) and m (multiplet). An LTQ Orbitrap Velos instrument (Thermo Scientific, Waltham, MA, USA) located at the Mass Spectrometry Laboratory of the Institute of Biochemistry and Biophysics PAS (Warsaw, Poland) was used to record high resolution mass spectra. A 6200 FT/IR spectrometer (Jasco, Easton, MD, USA) at the Laboratory of Optical Spectroscopy (Institute of Organic Chemistry PAS, Warsaw, Poland) was used to record IR spectra.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!