The largest database of trusted experimental protocols

Apex 2 d8 venture area

Manufactured by Bruker

The APEX-II D8 Venture is an X-ray diffractometer designed for single-crystal structure determination. It features a high-intensity microfocus X-ray source, a sophisticated goniometer, and a state-of-the-art detector system. The instrument is optimized for data collection and structural analysis of small-molecule and macromolecular crystals.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using apex 2 d8 venture area

1

Single Crystal Structure of Compound 3a

Check if the same lab product or an alternative is used in the 5 most similar protocols
Compound 3a was obtained as single crystals by slow evaporation at room temperature from dichloromethane–hexane (4:6) solution. Data were collected on a Bruker APEX-II D8 Venture area diffractometer equipped with graphite monochromatic Cu Kα radiation, λ = 1.54060 Å at 23 °C. Cell refinement and data reduction were carried out using Bruker SAINT. SHELXT [47 (link),48 ] was used to solve the structure. The final refinement was carried out by full-matrix least-squares techniques with anisotropic thermal data for non-hydrogen atoms on F. CCDC 1896391 contains the supplementary crystallographic data for this compound and can be obtained free of charge from the Cambridge Crystallographic Data Centre via www.ccdc.cam.ac.uk/data_request/cif.
+ Open protocol
+ Expand
2

Structural Analysis of IR3G Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The compound IR3G was obtained as single crystals by slow evaporation from MeOH solution of the pure compound at room temperature. Data were collected on a Bruker APEX-II D8 Venture area diffractometer, equipped with graphite monochromatic Cu Kα radiation, λ = 1.54178 Å at 293 (2) K. Cell refinement and data reduction were carried out by Bruker SAINT. SHELXT was used to solve the structure. The final refinement was carried out by full-matrix least-squares techniques with anisotropic thermal data for nonhydrogen atoms (Cambridge Crystallographic Data Center (CCDC 1545557) contains the supplementary crystallographic data for this compound and can be obtained free of charge via www.ccdc.cam.ac.uk/data_request/cif, accessed on 10 January 2022).
+ Open protocol
+ Expand
3

Crystal Structure Determination of Molecule 1

Check if the same lab product or an alternative is used in the 5 most similar protocols
As in reference7 (link) Molecule 1 was produced as single crystals by gradual evaporation of the pure compound in a solvent combination of chloroform and methanol at ambient temperature. Data were acquired using a Bruker APEX-II D8 Venture area diffractometer with graphite monochromatic Cu K radiation, = 1.54178 at 296 (2) K. Bruker SAINT performed cell refinement and data reduction. The structure was solved using SHELXT9 (link),10 (link). Full-matrix least-squares approaches using anisotropic thermal data for nonhydrogen atoms on F were used for the final refinement. The Cambridge Crystallographic Data Centre’s CCDC 2161839, which provides supplemental crystallographic data for this chemical, may be downloaded for free at https://www.ccdc.cam.ac.uk/datarequest/cif.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!