The operating conditions of mass spectrometry were as follows: electrospray ionization (ESI) source was employed, and positive and negative ion mode were selected; sheath gas flow, 40 A.U.; auxiliary gas flow, 20 and 10 A.U.; source voltage 3.8 kV; capillary temperature of 300 °C; capillary voltage 25 and −35 V; tube lens, 110 and −110 V. The samples were analyzed using FT full scan with mass in the m/z 100–1500 range. All the raw data were processed using Xcalibur 3.0 software19 (Thermo Fisher Scientific, Waltham, MA, USA).
Ltq orbitrap xl mass spectrometer system
The LTQ–Orbitrap XL mass spectrometer system is a high-performance analytical instrument designed for advanced mass spectrometry applications. It combines the sensitivity and resolution of the Orbitrap mass analyzer with the speed and versatility of the LTQ linear ion trap. The system is capable of performing accurate mass measurements and high-resolution tandem mass spectrometry (MS/MS) analysis.
Lab products found in correlation
2 protocols using ltq orbitrap xl mass spectrometer system
HPLC-MS Analysis of Supernatant Samples
The operating conditions of mass spectrometry were as follows: electrospray ionization (ESI) source was employed, and positive and negative ion mode were selected; sheath gas flow, 40 A.U.; auxiliary gas flow, 20 and 10 A.U.; source voltage 3.8 kV; capillary temperature of 300 °C; capillary voltage 25 and −35 V; tube lens, 110 and −110 V. The samples were analyzed using FT full scan with mass in the m/z 100–1500 range. All the raw data were processed using Xcalibur 3.0 software19 (Thermo Fisher Scientific, Waltham, MA, USA).
Comprehensive Profiling of HL Granule Components
Mass spectrometry data was acquired by LTQ ORBITRAP XL mass spectrometer system (Thermo Scientific, United States) both in the positive and negative ionization mode. The temperature of the heated capillary was 270°C and that of the ESI probe was 300°C. The flows of sheath gas and auxiliary gas were set to 40 and 10 units, respectively. The scan range of the Orbitrap analyzer was m/z 500–1800 and MSn data were acquired by LTQ in data dependent acquisition mode. Both of the positive and negative adopted the same MS parameters.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!