The largest database of trusted experimental protocols

Hp innowax fused silica capillary column

Manufactured by Agilent Technologies

The HP-INNOWax fused silica capillary column is a gas chromatography column designed for the separation and analysis of a wide range of analytes. It features a polyethylene glycol stationary phase coated on a fused silica support, providing efficient separation performance.

Automatically generated - may contain errors

3 protocols using hp innowax fused silica capillary column

1

Seed Fatty Acid Composition Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Seed fatty acid composition was analyzed according to [26] with the following modification: the gas chromatography of the methyl esters was performed with a HP-INNOWax fused silica capillary column (0.25 mm by 0.5 m and 7.5 µm) (Agilent Technologies) at 250°C using hydrogen as the carrier gas. A minimum of 10 seeds from each of the parental lines and F1 hybrids as well as 160 F2 seeds of each of the three crosses were half-seed analyzed according to [27] . Ninety-six seeds from each of the BC1 populations were analyzed using the single seed method.
+ Open protocol
+ Expand
2

GC-MS Analysis of Amino Acids

Check if the same lab product or an alternative is used in the 5 most similar protocols
GC-MS analysis was performed using a HP 7890B gas chromatograph (Agilent Technologies, Santa Clara, CA, USA) coupled with a 5977A mass selective detector (MSD) (Agilent Technologies) and a multi-purpose sampler MPS 2 (Gerstel, Mülheim an der Ruhr, Germany). HP-innowax fused silica capillary column (30 m length × 0.25 mm internal diameter × 0.25 μm film thickness; Agilent Technologies) was used with helium, a carrier gas, at a constant flow rate of 1 mL/min. Injection volume was 1.0 μL with split mode (20:1). The oven temperature program started at 40 °C initially and was held for 3 min, then was raised to 200 °C at 5 °C/min and held at 200 °C for 3 min. Post run was held at 180 °C for 2 min. Inlet, detector transfer line and mass source temperatures were 250, 280, 230 °C, respectively. MS was operated in the electron impact (EI) ion source mode at 70 eV with a scan range of 25~350 a.m.u. Ethanol (>99.9%) was purchased from Sigma-Aldrich (Sigma-Aldrich, St. Louis, MO, USA) for standard preparation. 4-Methyl-1-pentanol, an internal standard (ISTD) compound, was also obtained from Sigma-Aldrich. dl-alanine and dl-proline were purchased from Sigma-Aldrich and Oasis MAX cartridge 6 cc with stationary phase was purchased from Waters (Waters, Milford, MA, USA).
+ Open protocol
+ Expand
3

Seed Fatty Acid Composition Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Seed fatty acid composition was analyzed according to Thies (1971)41 with the following modification: the gas chromatography of the methyl esters was performed with a HP-INNOWax fused silica capillary column (0.25 mm by 0.5 m and 7.5 µm) (Agilent Technologies) at 250 °C using hydrogen as the carrier gas. A minimum of 10 seeds from each of the parental lines and F1 hybrids, and 150 F2 seeds of each of the crosses Y1798 × Y1801, Y1798 × Y514 and Y1801 × Y514 were half-seed analyzed according to Downey and Harvey (1963)42 (link).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!