The largest database of trusted experimental protocols

Ez run rec protein ladder

Manufactured by Thermo Fisher Scientific

The EZ-Run Rec Protein Ladder is a molecular weight standard used for estimating the size of proteins in polyacrylamide gel electrophoresis (PAGE) experiments. It contains a mixture of recombinant proteins with known molecular weights, allowing for the determination of the approximate molecular weights of unknown protein samples.

Automatically generated - may contain errors

7 protocols using ez run rec protein ladder

1

Protein Visualization and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The proteins in each fraction were visualized by sodium dodecyl sulfate–polyacrylamide gel electrophoresis using 4% to 12% polyacrylamide premade gradient gels (Novex NuPAGE; Invitrogen, Grand Island, NY) with 3-(N-morpholino)propanesulfonic acid as the running buffer (Invitrogen) followed by staining with Coomassie. EZ-Run Rec Protein Ladder (Fisher Scientific) was used as a protein standard. Coomassie Protein Assay Reagent (Thermo Scientific, Waltham, MA) was used to determine protein concentrations with bovine serum albumin as a standard.
+ Open protocol
+ Expand
2

Protein Quantification and Alignment

Check if the same lab product or an alternative is used in the 5 most similar protocols
SDS-PAGE was performed using 4-12% polyacrylamide pre-cast gels (Novex NuPAGE; Invitrogen) with MOPS running buffer (Invitrogen). EZ-Run™ Rec Protein Ladder was from Fisher. Gels were stained with SimplyBlue Safe Stain (Invitrogen). Protein concentrations were determined using protocols from Bradford [22 (link)] using bovine serum albumin as the standard. Protein alignments were prepared using Vector NTI Advance ® (Invitrogen).
+ Open protocol
+ Expand
3

SDS-PAGE Analysis of Protein Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
SDS-PAGE was performed using 4–12% polyacrylamide pre-cast gels (Novex NuPAGE; Invitrogen) with MOPS running buffer (Invitrogen). EZ-Run™ Rec Protein Ladder was from Fisher Scientific. Gels were stained with Simply Blue Safe Stain (Invitrogen). Protein concentrations were determined using Coomassie Protein Assay Reagent (Thermo Scientific) with bovine serum albumin as the standard.
+ Open protocol
+ Expand
4

SDS-PAGE Protein Separation and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS-PAGE) was performed using 4–12% polyacrylamide precast gels (Novex NuPAGE; Invitrogen, Grand Island, NY) with 3-(N-morpholino)propanesulfonic acid (MOPS) running buffer (Invitrogen). EZ-Run Rec Protein Ladder was from Fisher Scientific. Gels were stained with Simply Blue Safe Stain (Invitrogen). Protein concentrations were determined using Coomassie Protein Assay Reagent (Thermo Scientific, Waltham, MA) with bovine serum albumin as the standard.
+ Open protocol
+ Expand
5

SDS-PAGE Protein Visualization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Proteins were visualized by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) using 4–12% polyacrylamide precast gradient gels (Novex NuPAGE; Invitrogen, Grand Island, NY) with 3-(N-morpholino) propanesulfonic acid (MOPS) as the running buffer (Invitrogen). EZ-Run Rec Protein Ladder (Fisher Scientific) was used as a protein standard. Coomassie Protein Assay Reagent (Thermo Scientific, Waltham, MA) was used to determine protein concentrations with bovine serum albumin as a standard [8 (link)].
+ Open protocol
+ Expand
6

SDS-PAGE Protein Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS-PAGE) was performed using 4%–12% polyacrylamide precast gels (Novex NuPAGE, Invitrogen, Waltham, MA) with MOPS running buffer (Invitrogen). EZ-Run Rec Protein Ladder was from Fisher Scientific. Gels were stained with Simply Blue Safe Stain (Invitrogen). Protein concentrations were determined using Coomassie Protein Assay Reagent (Thermo Scientific, Waltham, MA) with bovine serum albumin as the standard.
+ Open protocol
+ Expand
7

SDS-PAGE Protein Separation and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS-PAGE) was performed using 4%–12% polyacrylamide precast gels (Novex NuPAGE; Invitrogen, Waltham, MA) with MOPS running buffer (Invitrogen). EZ-Run Rec Protein Ladder was from Fisher Scientific. Gels were stained with Simply Blue Safe Stain (Invitrogen). Protein concentrations were determined by the method of Bradford14 (link) using bovine serum albumin (BSA) as the standard.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists