The largest database of trusted experimental protocols

Eight camera motion capture system

Manufactured by Qualisys
Sourced in Sweden

The Eight camera motion capture system is a precision motion tracking solution that uses eight high-performance cameras to capture 3D movement data. The system is designed to provide accurate and reliable tracking of objects in a defined capture volume.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using eight camera motion capture system

1

Biomechanical Analysis of Running Gait

Check if the same lab product or an alternative is used in the 5 most similar protocols
Participants ran at 4.0 m/s ± 5%, striking a piezoelectric force platform (Kistler, Kistler Instruments Ltd) with their right (dominant) foot. Running velocity was monitored using infrared timing gates (Newtest, Oy Finland). The stance phase was delineated as the duration over which >20 N vertical force was applied to the force platform. Runners completed five successful trials in each footwear condition in a counterbalanced manner. Kinematic data was captured at 250 Hz via an eight camera motion capture system (Qualisys Medical AB, Goteburg, Sweden).
Lower extremity segments were modelled in 6 degrees of freedom using the calibrated anatomical systems technique (Cappozzo et al., 1995 ). Lower extremity segments were delineated in accordance with those of Sinclair (2014) . Static calibration trials were obtained in each footwear allowing the anatomical markers to be referenced in relation to the tracking markers/ clusters.
+ Open protocol
+ Expand
2

Anthropometric Data for Musculoskeletal Modeling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Anthropometric data from one healthy male subject (age: 26, mass: 70 kg, height:
178 cm) were acquired in the current study with the aim of setting the
musculoskeletal modelling background. The subject was initially equipped with 20
reflective skin markers attached to the pelvis, trunk, shoulder and right arm. The
position of the reflective markers was recorded using an eight-camera motion capture
system (Qualisys AS, Gothenburg, Sweden) at a sampling frequency of 100 Hz.
Kinematic data were analysed using the AnyBody Modelling System 6.1 (AMS) (AnyBody
Technology, Aalborg, Denmark), and a static trial was conducted in neutral position
as reference to scale the model to the subject.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!