Aquilion 64

Manufactured by Siemens
Sourced in Japan

The Aquilion 64 is a 64-slice computed tomography (CT) scanner manufactured by Siemens. It is a diagnostic imaging device designed to capture high-resolution, three-dimensional images of the body's internal structures.

Automatically generated - may contain errors

2 protocols using aquilion 64

1

Contrast-Enhanced CT for Mediastinal Tumor Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
All patients underwent contrast-enhanced CT before biopsy and/or surgery to evaluate suspected mediastinal tumors. Chest CT examinations were performed with either 320-row detector CT (Toshiba Aquilion ONE, Otawara-shi, Japan), 64-row detector CT (Toshiba Aquilion 64, Otawara-shi, Japan), or 16-row detector CT (Siemens Somatom Sensation 16, Forcheim, Germany) scanners. The acquisition parameters were 0.5 mm, 0.5 mm, and 0.625 mm detector collimation; 120 kVp tube voltage; 0.5 s gantry rotation time; 1 mm, 1 mm, and 1.5 mm reconstructed section thickness; and 0.8 mm, 0.8 mm, and 1 mm reconstruction intervals. All examinations were performed after injecting 60–100 ml (1–1.5 ml/kg) of nonionic intravenous contrast agent (350/100 Omnipaque, GE healthcare, Oslo, Norway), at a rate of 2.5 ml/s via the antecubital vein. The area from the thoracic inlet caudally to include the adrenal glands was scanned. All images were reviewed by a senior radiologist (Ç.U) with more than 10 years of experience in thoracic imaging. She was blinded to the histopathological data to avoid bias. Multiplanar reformatted images were analyzed on a workstation (GE Healthcare, Waukesha, WI, USA) (Figs. 1 and 2).

The lung extraction and 3D representation of tumor with lung structures

3D representation of regional segmentation of bronchus, artery, and vessels together with tumor volume

+ Open protocol
+ Expand
2

Helical CT Scanning Protocol for Lung Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
The CT scans were obtained using a helical technique with a 16-detector-row CT scanner (Toshiba Aquilion 16) or a 64-detector-row CT scanner (Toshiba Aquilion 64 and SOMATOM Definition, Siemens). Helical CT scans were obtained from the lung apex to the lung base. For all multi-detector-row CT scans, a section thickness of 1 mm, a helical pitch of 0.9, a reconstruction interval of 1 mm, a reconstruction with a lung kernel (FC51) and a mediastinum kernel (FC13), a tube potential of 120 kVp, and a tube current of 150 mA were used for scanning and image reconstruction. In 258 (80.4%) out of 321 cases, contrast-enhanced CT scans were performed using contrast media (Iopamidol 370; Bayer Yakuhin, Osaka) at 4.0 mL/s (total volume, 1 mL/kg) with a 20-mL saline chaser at 4.0 mL/s.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!