The largest database of trusted experimental protocols

Fk506 tac

Manufactured by Cayman Chemical

FK506 (TAC) is a chemical compound used as a laboratory reagent. It functions as an immunosuppressant that inhibits the activity of calcineurin, a protein phosphatase essential for T-cell activation.

Automatically generated - may contain errors

2 protocols using fk506 tac

1

Synthesis and Characterization of Poly(Lactide) MPs

Check if the same lab product or an alternative is used in the 5 most similar protocols
d,l-Lactide was purchased from TCI America, recrystallized three times in toluene, and stored at −30°C in a glove box prior to use. (BDI-EI)ZnN(TMS)2 was prepared by following reported procedures (Chamberlain et al., 2001 (link)). FK506 (TAC) (Cayman Chemical) was used as received. All other chemicals were obtained from Sigma-Aldrich and used as received unless otherwise noted. High-performance liquid chromatography (HPLC) analysis was performed on a System Gold system (Beckman Coulter). Infrared spectra were recorded on a PerkinElmer 100 serial Fourier transform infrared spectroscopy (FT-IR) spectrophotometer. MALDI-TOF MS spectra were collected on an Applied Biosystems Voyager-DETM STR system. The sizes and polydispersities of MPs were determined on a ZetaPALS dynamic light-scattering detector. The ζ potential of freshly prepared MPs was evaluated by Malvern Zetasizer. Lyophilization of MPs was completed on a benchtop lyophilizer (Freezone 2.5, Fisher Scientific. The sizes of MPs were characterized on a Hitachi S4700 high resolution scanning electron microscope.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Poly(Lactide) MPs

Check if the same lab product or an alternative is used in the 5 most similar protocols
d,l-Lactide was purchased from TCI America, recrystallized three times in toluene, and stored at −30°C in a glove box prior to use. (BDI-EI)ZnN(TMS)2 was prepared by following reported procedures (Chamberlain et al., 2001 (link)). FK506 (TAC) (Cayman Chemical) was used as received. All other chemicals were obtained from Sigma-Aldrich and used as received unless otherwise noted. High-performance liquid chromatography (HPLC) analysis was performed on a System Gold system (Beckman Coulter). Infrared spectra were recorded on a PerkinElmer 100 serial Fourier transform infrared spectroscopy (FT-IR) spectrophotometer. MALDI-TOF MS spectra were collected on an Applied Biosystems Voyager-DETM STR system. The sizes and polydispersities of MPs were determined on a ZetaPALS dynamic light-scattering detector. The ζ potential of freshly prepared MPs was evaluated by Malvern Zetasizer. Lyophilization of MPs was completed on a benchtop lyophilizer (Freezone 2.5, Fisher Scientific. The sizes of MPs were characterized on a Hitachi S4700 high resolution scanning electron microscope.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!