The largest database of trusted experimental protocols

Methacrylate anhydride

Manufactured by Merck Group
Sourced in United States

Methacrylate anhydride is a chemical compound used in various laboratory applications. It is a colorless liquid with a distinctive odor. Methacrylate anhydride is primarily utilized as a reagent or building block in chemical synthesis and research processes.

Automatically generated - may contain errors

11 protocols using methacrylate anhydride

1

Synthesis of Methacrylated Alginate Biopolymer

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methacrylated alginate (MeALG) was synthesized as described previously [85 (link),94 (link)]. Briefly, 0.5% (w/v) was prepared by dissolving 5 g of medium viscosity alginate (alginic acid sodium salt from brown algae, Sigma-Aldrich Inc., St. Louis, MO, USA) in 1 L of DI water. The solution was kept under magnetic stirring at 1–4 °C. Once the alginate was fully dissolved, 10 mL of methacrylate anhydride (MA, Sigma-Aldrich Inc., St. Louis, MO, USA) was added dropwise into the solution within a span of 1.5–2 h. 2 M NaOH solution (Sigma-Aldrich Inc., St. Louis, MO, USA) was simultaneously added dropwise to adjust the pH of the solution to 8–9. After the addition of the MA, pH of the mixture was maintained by gradually dripping 2 M NaOH solution for 8 h using an automated pH controller. The solution was kept at 4 °C overnight. The reaction was resumed the following day by adding 5 mL of MA while maintaining the pH at 8–9. The material was then dialyzed (Spectra/Por®1 dialysis membrane, 6–8 kDa, Fisher Scientific, Pittsburgh, PA, USA) against DI water for 5 days and lyophilized using a benchtop freeze dryer (Labconco FreeZone 4.5 L, Fisher Scientific, Pittsburgh, PA, USA). 1H NMR (Bruker Advance III HD 500 MHz, Bruker Scientific, Billerica, MA, USA) was used to confirm the methacrylate percentage as described previously [85 (link)].
+ Open protocol
+ Expand
2

Photocrosslinkable Gelatin-Hyaluronic Acid Hydrogel

Check if the same lab product or an alternative is used in the 5 most similar protocols
Hyaluronic acid (molecular weight of 2000 kDa) was purchased from Kikkoman (FCH-200, Tokyo, Japan). Gelatin from porcine skin (type B) and methacrylate anhydride (MA) (molecular weight of 154.16 Da) were purchased from Sigma-Aldrich, St. Louis, MO, USA). The P.I. of lithium phenyl-2,4,6-trimethyl-benzoyl phosphinate (LAP), nano-silica (SiO2; nSi), 3-acryloxypropyl trimethoxysilane (APMS) were also obtained from Sigma-Aldrich (St. Louis, MO, USA), and the sodium carbonate anhydrous (Na2CO3) and sodium bicarbonate (NaHCO3) were purchased from J.K Baker (Phillipsburg, NJ, USA). The other reagents, such as phosphate-buffered saline (PBS), Dulbecco’s Modified Eagle’s Medium (DMEM), fetal bovine serum (FBS), penicillin, and streptomycin were purchased from Gibco BRL (Grandland, New York, NY, USA). All other solvents were purchased from Merck (Darmstadt, Germany), TEDIA (Fairfield, CT, USA), or J. T. Baker (Phillipsburg, NJ, USA). These chemicals were all analytical/reagent grade and were used without further purification.
+ Open protocol
+ Expand
3

Methacrylated Hyaluronic Acid Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
MeHA was synthesized as previously described18 (link),19 (link). In brief, 50 kDa sodium hyaluronate (Lifecore Biomedical, HA40K) was dissolved in deionized water at 1% w/v overnight and reacted with methacrylate anhydride (Sigma-Aldrich, 276685, 6 ml methacrylate anhydride per 1 g sodium hyaluronate) for 8 h on ice at pH 8, followed by overnight incubation at 4 °C, and further reacted with methacrylate anhydride (3 ml methacrylate anhydride per 1 g sodium hyaluronate) at pH 8 on ice for 4 h. The monomer solution was then dialysed (Spectrum Labs, 132655) against deionized water at 4 °C for 3 days followed by lyophilization for another 3 days. The lyophilized MeHA was analysed by 1H magnetic resonance (NMR) to determine the methacrylate substitution ratio by normalization of the peaks at a chemical shift of 6 ppm, representing the methacrylate group, by peaks between 3 and 4 ppm, which represent native HA. Substitution ratios were computed from triplicate NMR analyses (Fig. 1a).
+ Open protocol
+ Expand
4

Gelatin-Based Photocrosslinkable Hydrogels

Check if the same lab product or an alternative is used in the 5 most similar protocols
Gelatin (Type A, 300 bloom from porcine skin), methacrylate anhydride (MA), NaOH pellets, NaCl, 3-(trimethoxysilyl)-propyl methacrylate (TMSPMA), and ferritin and apoferritin (both from equine spleen) were purchased from Sigma-Aldrich (St. Louis, Missouri). Irgacure 2959 (2-hydroxy-1-(4-(hydroxyethoxy)-phenyl)-2-methyl-1-propanone), as a photoinitiator (PI), was acquired from Ciba Specialty Chemicals Incorporated (Basel, Switzerland). Dulbecco’s phosphate-buffered saline (DPBS), Dulbecco’s modified Eagle’s medium (DMEM), fetal bovine serum (FBS), and penicillin–streptomycin were bought from Invitrogen (Waltham, Massachusetts). Dialysis membrane tubes, Slide-A-Lyzer Dialysis cassette, glass slides, and coverslips were purchased from Thermo Fisher Scientific (Waltham, Massachusetts). Alexa Fluor 488 Phalloidin, 4′,6-diamidino-2-phenylindole (DAPI), LIVE/DEAD kit, and fluoraldehyde o-phthaldialdehyde (OPA) were acquired from Thermo Fisher Scientific (Waltham, Massachusetts). Omnicure S2000 (EXFO Photonic Solutions Incorporation, Quebec City, Canada) was used for photo-cross-linking. The device for mechanical testing was the 5942 Single Column Tabletop Model testing system from Instron, an ITW company (Illinois Tool Works Incorporation, Glenview, Illinois).
+ Open protocol
+ Expand
5

Calcium-Gelatin Biomaterial Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
We obtained calcium chloride (CaCl2), sodium hydroxide (NaOH), H2O2, 30%, ammonium hydroxide solution (50%), gelatin, methacrylate anhydride, and PCL with 80,000 molecular weight from Sigma-Aldrich. Dichloromethane (DCM) was from Merck Millipore. A live/dead cell imaging kit (Invitrogen-Molecular probes) and Alizarin red S was obtained from Thermo Fisher Scientific. Polyethylene glycol 200 (PEG200) was from Fisher Scientific. The following were sourced from Gibco: phosphate-buffered saline (PBS), Dulbecco′s modified Eagle’s medium (DMEM), catalase (H2O2:H2O2 oxidoreductase, EC 1.11.1.6), penicillin streptomycin solution, trypsin-ethylenediaminetetraacetic acid (EDTA), and fetal bovine serum. The tissue culture flasks and plates used in this research were from GenClone, Genesee Scientific (San Diego, CA, USA).
+ Open protocol
+ Expand
6

Synthesis and Characterization of GelMA

Check if the same lab product or an alternative is used in the 5 most similar protocols
GelMA was synthesized according to previously reported methods76 (link),77 (link). In brief, type A gelatin from cold-water fish skin (10 g, Mw = 60 kDa, Sigma-Aldrich, USA) was dissolved in phosphate-buffered saline (100 mL, PBS, ThermoFisher, USA) at the concentration of 10%. Methacrylate anhydride (12 mL, MA, Sigma-Aldrich) was then added dropwise and was reacted with gelatin solution at 50 °C for 2 h. After diluting the solution 1:1 with warm PBS (40 °C) to stop the reaction, dialysis was conducted for 7 days against deionized (DI) water using dialysis membrane (Mw cut off (MWCO): 12–14 kDa, Spectrum Chemical, USA) at 40 °C to remove low-molecular weight impurities. Subsequently, the solution was lyophilized and stored at −20 °C in dark until use. The lyophilized GelMA was further characterized by 1H NMR spectroscopy (Bruker Avance II 300-MHz NMR, USA). NMR data were processed with the MestreNova (6.2.0) software. The primary amine contents of gelatin and synthesized GelMA were evaluated by TNBSA assay78 (link).
+ Open protocol
+ Expand
7

Fabrication of Light-Curable Cornea Hydrogels

Check if the same lab product or an alternative is used in the 5 most similar protocols
To fabricate light-curable (LC) COMatrix hydrogel from the porcine corneas decellularized with detergent-based or freeze–thaw methods, the already produced thermoresponsive COMatrix hydrogels were reacted with methacrylate anhydride (Sigma, USA) at 4 °C in the dark for 12 h, as previously reported30 . Then, the samples were dialyzed against deionized water for 3 days at room temperature using 12–14 kDa MWCO dialysis tubes. The functionalized COMatrix was freeze-dried for 3 days and kept in − 80 °C for further experiments. To prepare the LC-COMatrix solution for experiments, the lyophilized samples were dissolved in a photo-initiating cocktail including Eosin Y, Ethanolamine, and N-Vinylcaprolactam as described before30 . Afterward, the LC-COMatrices were cured with green light (520 nm wavelength) to induce photogelation. The light-curable COMatrix hydrogels derived from detergent-based decellularization protocol called, De-LC-COMatrix; and, light-curable hydrogels derived from freeze–thaw decellularization method called, FT-LC-COMatrix.
+ Open protocol
+ Expand
8

Synthesis of Functional Polymeric Materials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dopamine hydrochloride (DOPA-HCl, 98%), methacrylate anhydride (MAA, 95%), methoxyethyl acrylate (MEA, 98%), 1-adamantanecarboxylic acid chloride (98%), 2,2′-azobisisobutyronitrile (AIBN, 98%), hexane (99%), tetrahydrofuran (THF), and anhydrous dimethyl formamide (DMF) are purchased from Sigma-Aldrich. Sodium borate, ethyl acetate, sodium bicarbonate, magnesium sulfate, and sodium hydroxide are purchased from Meyer. Before utilization, methacrylate anhydride is passed through a column packed with Al2O3 to remove the inhibitor, and AIBN is recrystallized twice from methanol.
+ Open protocol
+ Expand
9

Hydrogel Synthesis and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Iron (II) chloride tetrahydrate (purity > 99.0%, product no. 44939), Iron (III) chloride hexahydrate (purity > 99.0%, product no. 31232), type A gelatin from porcine skin (Gel strength 300, product no. G2500), methacrylate anhydride (MA) (purity ≥ 94.0%, product no. 276685), 2-Hydroxy-4′-(2-hydroxyethoxy)-2-methylpropiophenone (Irgacure 2959) (purity ≥ 97.5%, product no. 410896), and alginic acid salt (low viscosity (4–12 cps), product no. A1112) were purchased from Sigma-Aldrich (St. Louis, MO, USA). Calcium chloride (CaCl2) (purity = 93.0%, product no. 12316, Alfa Aesar, Haverhill, MA, USA) was purchased from Thermo Fisher Scientific Inc. (Waltham, MA, USA)
+ Open protocol
+ Expand
10

Synthesis of Isosorbide Dimethacrylate and Urethane Acrylate

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals used in this study were as follows: isosorbide (1,4:3,6-dianhydro-D-sorbitol, 98%), methacrylate anhydride (94%), ethyl 4-N,N-dimethylaminobenzoate (EDMAB), tetrahydrofuran (THF, anhydrous, 99.9%), and magnesium sulfate (MgSO4, 99.5%) were purchased from Sigma-Aldrich. Triethylamine (TEA) and 4,4-dimethylaminopyridine (DMAP) were purchased from Daejung for isosobide dimethacrylate (ISDM). Poly(tetramethylene ether)glycol (PTMG, average Mn 1000 g/mol), isophorone diisocyanate (IPDI, 98%), and diphenyl (2,4,6-trimethylbenzoyl)phosphine oxide (TPO, Shinyoun Rad Chem Ltd.) were also purchased from Aldrich, Korea, for the synthesis of PTMG-based urethane acrylate. ISDM (Fig. 1f) was synthesized as shown in Fig. S433 (link).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!