Synthesis of Example 23 Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 23

To 23c-int (0.4 g) in THF (10 mL)/H2O (10 mL) was added LiOH. H2O (0.16 g, 3.78 mmol). The mixture was stirred for 2 h at 30° C. then was concentrated and purified by prep-HPLC to give Example 23.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: TFA/H2O=0.075% v/v; B: AcN (gradient % B at T=0: 10%; at T=12 min: 30%); Column: Luna C18 100×30 5 u; Flow rate: 20 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, CHLOROFORM-d): δ ppm 2.03-1.97 (m, 2H) 2.59-2.49 (m, 3H) 3.21 (t, J=10.4 Hz, 2H) 3.89 (d, J=5.2 Hz, 3H) 5.12-5.07 (m, 1H) 5.42 (s, 1H) 6.38 (d, J=7.6 Hz, 1H) 6.69-6.63 (m, 2H) 6.77 (d, J=8.8 Hz, 2H) 7.15 (d, J=8.8 Hz, 2H) 7.28-7.22 (m, 3H) 7.79-7.74 (m, 2H) 9.67 (s, 1H); LCMS (ESI+): m/z=514.0 (M+H)+, RT: 2.2 min; HPLC purity: 95.3%, RT: 6.2 min; Chiral SFC purity: 100%, ee value: 100%, RT: 3.4 min.

+ Open protocol
+ Expand
2

Purification of Example 52 Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 52

52f-int (40 mg, 80.09 umol) and LiOH.H2O (10.08 mg, 240.27 umol) in THF (2 mL)/H2O (500 uL) was stirred at 20° C. for 12 hrs. LCMS showed the reaction was complete. The mixture was concentrated in vacuum and the residue was purified by prep-HPLC to give Example 52.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system: Mobile phase A: TFA/H2O=0.075% v/v; B: AcN (gradient % B at T=0: 11%; at T=10 min: 41%); Column: Boston Green ODS 150×30 5 u; Flow rate: 25 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, METHANOL-d4): δ ppm 7.31-7.48 (m, 3H), 4.63 (dd, J=9.48, 4.63 Hz, 1H), 4.39 (s, 2H), 4.03 (s, 2H), 3.23-3.29 (m, 2H), 3.00 (s, 3H), 1.89-2.00 (m, 1H), 1.73-1.84 (m, 1H), 1.62-1.73 (m, 1H), 1.68 (quin, J=7.06 Hz, 1H), 1.50-1.59 (m, 2H), 1.40 (br s, 8H); LCMS (ESI+): m/z=485.1 (M+H)+, RT: 2.0 min; HPLC purity: 95.4%, RT: 5.6 min; Chiral SFC purity: 100%, ee value: 100%, RT: 2.7 min.

+ Open protocol
+ Expand
3

Purification of Example 47 via HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 47

47h-int (70.00 mg, 125.56 umol) in HCl/EtOAc (15 mL) was stirred at 25° C. for 2 hours. LC-MS showed 47h-int was consumed completely and Example 47 was detected. The reaction mixture was concentrated and was purified by prep-HPLC to give Example 47.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: TFA/H2O=0.075% v/v; B: AcN (gradient % B at T=0: 5%; at T=10 min: 35%); Column: Luna C18 100×30 5 u; Flow rate: 25 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, METHANOL-d4): δ ppm 7.37-7.48 (m, 3H), 4.63 (dd, J=9.48, 4.63 Hz, 1H), 4.10 (br s, 2H), 3.60-3.64 (m, 2H), 3.42 (br s, 2H), 3.26 (t, J=7.17 Hz, 2H), 1.90-2.00 (m, 1H), 1.79 (ddt, J=13.75, 9.34, 6.86, 6.86 Hz, 1H), 1.63-1.71 (m, 2H), 1.50-1.58 (m, 2H), 1.40 (br s, 8H); LCMS (ESI+): m/z=457.2 (M+H)+, RT: 2.1 min; HPLC purity: 79.1%, RT: 4.8 min; Chiral SFC purity: 100%, ee value: 100%, RT: 2.6 min.

+ Open protocol
+ Expand
4

Synthesis and Purification of Example 57

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 57

To a solution of 58a-int (80 mg, 149.42 umol) in H2O (800 uL) was added HCl (12 N, 12.45 uL) and AcOH (8.97 mg, 149.42 umol, 8.54 uL). The mixture was stirred at 70° C. for 12 hrs. LC-MS showed 57a-int was consumed completely and one main peak with desired MS for Example 57 was detected. The reaction mixture was concentrated and was purified by prep-HPLC to give Example 57.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: TFA/H2O=0.075% v/v; B: AcN (gradient % B at T=0: 14%; at T=10.5 min: 34%); Column: Boston Green ODS 150×30 5 u; Flow rate: 25 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, METHANOL-d4): δ ppm 7.32-7.39 (m, 3H), 7.22 (d, J=8.60 Hz, 2H), 6.82-6.85 (m, 2H), 4.87-4.89 (m, 1H), 4.22 (s, 2H), 4.00-4.05 (m, 2H), 3.47 (br t, J=6.73 Hz, 2H), 3.21 (dd, J=14.22, 5.40 Hz, 1H), 3.12-3.15 (m, 3H), 2.96 (dd, J=14.22, 9.15 Hz, 1H), 1.85-1.93 (m, 4H); LCMS (ESI+): m/z=521.0 (M+H)+, RT: 2.3 min; HPLC purity: 97.2%, RT: 5.5 min; Chiral SFC: purity: 100%, ee value: 100%, RT: 2.8 min.

+ Open protocol
+ Expand
5

Synthesis and Purification of Example 20

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 20

To a solution of 20a-int (150 mg, 305.86 umol) in THF (2 mL)/H2O (2 mL) was added LiOH. H2O (12.83 mg, 305.86 umol). This was stirred for 12 hrs at 20° C. after which LCMS showed the desired product was present and the reaction complete. The solvent was removed and the crude material was purified by prep-HPLC to give Example 20.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: TFA/H2O=0.075% v/v; B: AcN (gradient % B at T=0: 20%; at 11.5 min: 40%); Column: Boston Green ODS 150×30 5 u; Flow rate: 25 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, METHANOL-d4): 7.56 (d, J=7.2 Hz, 1H), 7.35-7.41 (m, 3H), 6.60 (d, J=7.2 Hz, 1H), 5.52-5.63 (m, 1H), 4.60-4.64 (m, 1H), 3.44-3.46 (m, 2H), 2.78-2.79 (m, 2H), 2.68-2.76 (m, 2H) 2.64-2.66 (m, 1H), 2.05-2.08 (m, 2H), 1.89-1.92 (m, 2H), 1.65-1.67 (m, 2H), 1.43-1.46 ppm (m, 2H); LCMS (ESI+): m/z=476.0 (M+H)+, RT=2.3 min; HPLC: RT=4.9 min, purity: 90.9%; Chiral SFC purity: 100%, e.e. value: 100%, RT=3.3 min.

+ Open protocol
+ Expand
6

Synthesis and Purification of Example 23

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 23

To 23c-int (0.4 g) in THF (10 mL)/H2O (10 mL) was added LiOH. H2O (0.16 g, 3.78 mmol). The mixture was stirred for 2 h at 30° C. then was concentrated and purified by prep-HPLC to give Example 23.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: TFA/H2O=0.075% v/v; B: AcN (gradient % B at T=0: 10%; at T=12 min: 30%); Column: Luna C18 100×30 5 u; Flow rate: 20 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, CHLOROFORM-d): δ ppm 2.03-1.97 (m, 2H) 2.59-2.49 (m, 3H) 3.21 (t, J=10.4 Hz, 2H) 3.89 (d, J=5.2 Hz, 3H) 5.12-5.07 (m, 1H) 5.42 (s, 1H) 6.38 (d, J=7.6 Hz, 1H) 6.69-6.63 (m, 2H) 6.77 (d, J=8.8 Hz, 2H) 7.15 (d, J=8.8 Hz, 2H) 7.28-7.22 (m, 3H) 7.79-7.74 (m, 2H) 9.67 (s, 1H); LCMS (ESI+): m/z=514.0 (M+H)+, RT: 2.2 min; HPLC purity: 95.3%, RT: 6.2 min; Chiral SFC purity: 100%, ee value: 100%, RT: 3.4 min.

+ Open protocol
+ Expand
7

Synthesis and Purification of Example 54

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 54

To 54c-int (65 mg, 133.07 umol) in THF (3 mL)/H2O (1 mL) was added LiOH.H2O (11.17 mg, 266.14 umol). The mixture was stirred at 25° C. for 12 hours. LCMS showed 54c-int was consumed and one main peak for Example 54 was detected. The mixture was adjusted to pH 6 with aqueous HCl (1N) then concentrated and purified by prep-HPLC to give Example 54.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: 10 mM NH4HCO3 in H2O; B: AcN (gradient % B at T=0: 30%; at T=12 min: 50%); Column: YMC-Actus Triart C18 150×30 5 u; Flow rate: 25 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, METHANOL-d4): δ ppm 7.32-7.47 (m, 3H), 4.62 (dd, J=9.15, 4.74 Hz, 1H), 3.51 (br t, J=5.51 Hz, 2H), 3.20-3.29 (m, 4H), 2.13-2.22 (m, 2H), 1.88-2.00 (m, 1H), 1.71-1.84 (m, 1H), 1.57-1.68 (m, 2H), 1.48-1.56 (m, 1H), 1.48-1.49 (m, 1H), 1.38 (br s, 8H); LCMS (ESI+): m/z=474.0 (M+H)+, RT: 2.5 min; HPLC purity: 97.6%, RT: 6.3 min; Chiral SFC purity: 99.1%, ee value: 98.2%, RT: 3.0 min.

+ Open protocol
+ Expand
8

Hydrolysis and Purification of 22f-int

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 22

To 22f-int (100 mg, 185.37 umol) in THF (5 mL) was added LiOH (13.32 mg, 556.12 umol) and H2O (2 mL), then the mixture was stirred at 40° C. for 12 hrs. After this time LCMS showed the reaction was complete. The mixture was concentrated then purified by prep-HPLC to give Example 22.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: TFA/H2O=0.075% v/v; B: AcN (gradient % B at T=0: 12%; at 10.5 min: 34%); Column: Boston Green ODS 150×30 5 u; Flow rate: 25 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, METHANOL-d4): 6 ppm 7.63 (d, J=7.2 Hz, 1H), 7.32-7.36 (m, 3H), 7.17 (d, J=8.4 Hz, 2H), 6.83 (d, J=7.5 Hz, 1H), 6.50 (d, J=8.4 Hz, 2H), 4.81 (br s, 1H), 4.16-4.23 (m, 2H), 3.90 (br d, J=2.8 Hz, 2H), 3.47-3.53 (m, 2H), 3.27-3.28 (m, 1H), 3.17 (dd, J=14.0, 5.52 Hz, 1H), 2.92 (dd, J=14.2, 9.2 Hz, 1H), 2.83 (t, J=6.4 Hz, 2H), 1.92-2.00 (m, 2H); LCMS (ESI+): m/z=525.0 (M+H)+, RT: 2.5 min; HPLC purity: 90.5%, RT: 6.2 min; Chiral SFC purity: 87.3%, ee value: 74.5%, RT: 1.3 min.

+ Open protocol
+ Expand
9

Synthesis and Purification of Compound 53

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 53

A mixture of compound 53d-int (100 mg, 200.23 umol) and LiOH.H2O (8.40 mg, 200.23 umol) in THF (5 mL)/H2O (1 mL) was stirred at 20° C. for 1 hr. LCMS showed desired MS; the mixture was concentrated and the residue was purified by prep-HPLC (TFA) to give Example 53.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: TFA/H2O=0.075% v/v; B: AcN (gradient % B at T=0: 25%; at T=12 min: 55%); Column: YMC-Actus Triart C18 150×30 5 u; Flow rate: 25 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, METHANOL-d4): δ ppm 7.30-7.50 (m, 3H), 4.62 (dd, J=9.26, 4.63 Hz, 1H), 3.59-3.74 (m, 4H), 3.33 (s, 2H), 3.11 (s, 3H), 1.87-2.01 (m, 1H), 1.72-1.85 (m, 1H), 1.60-1.71 (m, 2H), 1.47-1.59 (m, 2H), 1.38 (br s, 8H); LCMS (ESI+): m/z=485.2 (M+H)+, RT: 2.4 min; HPLC purity: 90.6%, RT: 5.8 min; Chiral SFC purity: 100%, ee value: 100%, RT: 2.6 min.

+ Open protocol
+ Expand
10

Synthesis and Purification of Example 51

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 51

To 51c-int (100 mg, 211.69 umol) in THF (5 mL) and H2O (2 mL) was added LiOH.H2O (17.77 mg, 423.38 umol); the mixture was stirred at 25° C. for 2 hours. LCMS showed 51c-int was consumed completely and one main peak with desired MS was detected. The mixture was concentrated and adjusted to pH 6 with aq. HCl (1N) and was concentrated in vacuum. The residue was purified by prep-HPLC to give Example 51.

HPLC purification conditions: Gilson 281 semi-preparative HPLC system; Mobile phase A: 10 mM NH4HCO3 in H2O; B: AcN (gradient % B at T=0: 25%; at T=12 min: 45%); Column: YMC-Actus Triart C18 150×30 5 u; Flow rate: 25 mL/min; Monitor wavelength: 220 & 254 nm.

1H NMR (400 MHz, METHANOL-d4): 6 ppm 7.33-7.47 (m, 3H), 4.56 (dd, J=8.27, 4.74 Hz, 1H), 3.21-3.30 (m, 6H), 1.86-2.00 (m, 3H), 1.71-1.84 (m, 1H), 1.45-1.58 (m, 4H), 1.26-1.42 (m, 7H), 1.25-1.26 (m, 1H); LCMS (ESI+): m/z=458.0 (M+H)+, RT: 2.5 min; HPLC purity: 100%, RT: 6.5 min; Chiral SFC purity: 100%, ee value: 100%, RT: 3.0 min.

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!