The largest database of trusted experimental protocols

Lc q tof ms 6520 spectrometer

Manufactured by Agilent Technologies

The Agilent LC-Q-TOF-MS 6520 spectrometer is a high-resolution, accurate-mass liquid chromatography-quadrupole time-of-flight mass spectrometer. It combines liquid chromatography separation with high-resolution, accurate-mass mass spectrometry to provide comprehensive analysis of complex samples.

Automatically generated - may contain errors

3 protocols using lc q tof ms 6520 spectrometer

1

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents from commercial suppliers were used without further purification. All solvents were freshly distilled before use from appropriate drying agents. All other reagents were recrystallized or distilled when necessary. Analytical TLCs were performed with silica gel 60 F254 plates. Visualization was accomplished by UV light. Column chromatography was carried out using silica gel 60 (230–400 mesh ASTM). NMR spectra were obtained on a Bruker Avance 500 MHz spectrometers and recorded at 25°C. Chemical shifts for 1H-NMR spectra are reported in ppm downfield from TMS, chemical shifts for 13C-NMR spectra are recorded in ppm relative to internal deuterated chloroform (δ = 77.2 ppm for 13C). Coupling constants (J) are reported in Hertz. The terms m, s, d, t, q refers to multiplet, singlet, doublet, triplet, quartet. 13C-NMR were broadband decoupled from hydrogen nuclei. High resolution mass spectra (HRMS) was measured by EI method with a Agilent LC-Q-TOF-MS 6520 spectrometer.
+ Open protocol
+ Expand
2

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents from commercial suppliers were used without further purification. All solvents were freshly distilled before use from appropriate drying agents. All other reagents were recrystallized or distilled when necessary. Reactions were performed under a dry nitrogen atmosphere. Analytical TLCs were performed with silica gel 60 F254 plates. Visualization was accomplished by UV light. Column chromatography was carried out using silica gel 60 (230–400 mesh ASTM). Melting points were determined with an Electrothermal IA9100 Digital Melting Point Apparatus without correction. NMR spectra were obtained on a Bruker Avance 400 MHz and a Varian VXR 300 MHz spectrometer and recorded at 25 °C. Chemical shifts for 1H NMR spectra are reported in ppm downfield from TMS, chemical shifts for 13C NMR spectra are recorded in ppm relative to internal deuterated chloroform (δ = 77.2 ppm for 13C), chemical shifts for 19F NMR are reported in ppm downfield from fluorotrichloromethane (CFCl3). Coupling constants (J) are reported in Hertz. The terms m, s, d, t, q refer to multiplet, singlet, doublet, triplet, quartet. 13C NMR and 19F NMR were broadband decoupled from hydrogen nuclei. High-resolution mass spectra (HRMS) were measured by the EI method with an Agilent LC-Q-TOF-MS 6520 spectrometer.
+ Open protocol
+ Expand
3

Synthesis and Characterization of Fluorinated Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents from commercial suppliers were used without further purification. All solvents were freshly distilled before use from appropriate drying agents. All other reagents were recrystallized or distilled when necessary. Reactions were performed under a dry nitrogen atmosphere. Analytical thin layer chromatography (TLC) was performed with silica gel 60 F254 plates. Visualization was accomplished by UV light. Column chromatography was carried out using silica gel 60 (230–400 mesh ASTM). Melting points were determined with an Electrothermal IA9100 Digital Melting Point Apparatus without correction. NMR spectra were obtained on Bruker Avance 400 MHz and Varian VXR 300 MHz spectrometers and recorded at 25 °C. Chemical shifts for 1H NMR spectra are reported in ppm downfield from TMS, chemical shifts for 13C NMR spectra are recorded in ppm relative to internal deuterated chloroform (δ = 77.2 ppm for 13C), and chemical shifts for 19F NMR are reported in ppm downfield from fluorotrichloromethane (CFCl3). Coupling constants (J) are reported in Hertz. The terms m, s, d, t, and q refer to multiplet, singlet, doublet, triplet, and quartet, respectively. 13C NMR and 19F NMR were broadband decoupled from hydrogen nuclei. High-resolution mass spectra (HRMS) were measured by EI method with an Agilent LC-Q-TOF-MS 6520 spectrometer.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists