The largest database of trusted experimental protocols

Tof tof 5800 system software

Manufactured by AB Sciex
Sourced in Canada

The TOF/TOF 5800 System Software is a software component designed to operate the TOF/TOF 5800 System, a high-performance mass spectrometry instrument manufactured by AB Sciex. The software provides the necessary functionality to control the instrument, acquire data, and process the resulting mass spectra.

Automatically generated - may contain errors

2 protocols using tof tof 5800 system software

1

Analytical Characterization of Protein Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
The molecular weight and the haptenation ratio (the hapten:carrier protein molar ratio) were calculated [((MW hapten + carrier protein) – MW carrier protein)/MW of hapten] for each conjugate using an Applied Biosystems/MDS SCIEX 5800 MALDI TOF/TOF analyzer (Foster City, CA) and TOF/TOF 5800 System Software (SCIEX, Concord, Ontario, Canada). The instrument operated in a high-mass linear mode. Samples were desalted on a ZipTip C4 (Merk Millipore, Burlington, MA) prior to analysis. Bovine serum albumin (BSA) was used to calibrate the instrument.
+ Open protocol
+ Expand
2

Characterization of Protein Conjugates by MALDI-TOF and DLS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The molecular weight (MW) of BSA and CRM-containing conjugates was assessed before and after conjugation using an Applied Biosystems/MDS SCIEX 5800 MALDI TOF/TOF analyzer (Foster City, CA) and TOF/TOF 5800 System Software (SCIEX, Concord, Ontario, Canada). Each sample was assigned a spot and mixed with a saturated sinapinic acid matrix on a 384 opti-tof 123 × 81 mm Rev A plate. Data were acquired in the linear high mass positive acquisition mode. The resulting haptenization ratio (number of haptens per mole of protein) of each conjugate was calculated as follows: [(MWconjugate − MWcarrier protein)/MWhapten]. Due to their large molecular weight, the haptenization ratio of sKLH conjugates could not be determined by MALDI-TOF and was consequently characterized for size by DLS on a Zetasizer (Malvern Panalytical Inc., United Kingdom) as described previously.47
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!