Gammacoat plasma renin activity 125 1 radioimmunoassay kit

Manufactured by DiaSorin
Sourced in United States

The GammaCoat Plasma Renin Activity 125 I Radioimmunoassay Kit is a laboratory diagnostic product designed to quantitatively measure the levels of renin activity in plasma samples. It utilizes a radioimmunoassay technique with a 125I-labeled tracer to detect and quantify the target analyte.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using gammacoat plasma renin activity 125 1 radioimmunoassay kit

1

RAAS Activation in Heart Failure Patients

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma samples from patients enrolled in both DOSE-AHF and CARRESS-HF were collected a baseline and at 72 hours (DOSE-AHF) or 96 hours (CARRESS-HF) and analyzed at a central core laboratory blinded to treatment assignment. RAAS activation was characterized by serum plasma renin activity (PRA) and aldosterone. PRA was measured by GammaCoat Plasma Renin Activity 125 I Radioimmunoassay Kit (catalog #CA-1533) by Diasorin (Stillwater, MN). Expected values for PRA are 0.85-16.34 ng/mL/hr and the inter-assay CV provided by the manufacturer is less than 10%. Aldosterone was measured by a radioimmunoassay manufactured by Diasorin (catalog #ALDOCTK-2). Expected values for Aldosterone in normal, healthy individuals are 7.5-150 pg/mL. The inter-assay CV provided by the manufacturer is less than 5.3%.
+ Open protocol
+ Expand
2

Quantification of Mast Cell-Derived Renin

Check if the same lab product or an alternative is used in the 5 most similar protocols
Determination of mast cell-derived renin has been used as an additional suitable marker of mast cell degranulation induced by I/R. Thus, as a further test of potential inhibitory effects of 4CPI on mast cell degranulation, we evaluated a possible reduction of mast cell-derived renin in 4CPI-treated hearts submitted to I/R.
Renin activity was measured in samples collected from coronary effluent using a GammaCoat Plasma Renin Activity 125I Radioimmunoassay kit (DiaSorin, Stillwater, MN, USA) according to the manufacturer's instructions. Briefly, 200 l each sample of coronary effluent were incubated with porcine angiotensinogen (0.1 mg/ml), maleate buffer and PMSF (part of the DiaSorin kit). The reaction for angiotensin I production was conducted for 1.5 h at 37 • C. Results were normalized to total heart weight. The detection limit was approximately 0.01 pmol.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!