The largest database of trusted experimental protocols

Acquity uplc class 1 xevo g2q tof mass spectrometer

Manufactured by Waters Corporation
Sourced in United States

The Acquity UPLC Class I/Xevo G2Q-Tof mass spectrometer is a high-performance liquid chromatography and mass spectrometry system developed by Waters Corporation. It is designed to provide accurate, sensitive, and reliable analysis of a wide range of chemical compounds.

Automatically generated - may contain errors

2 protocols using acquity uplc class 1 xevo g2q tof mass spectrometer

1

High-Resolution Mass Spectrometry and NMR Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Waters Acquity UPLC Class I/Xevo G2Q-Tof mass spectrometer (Milford, MA, USA) was used to obtain the high-resolution ESI-MS (HR-ESI-MS) data. 1H and 13C NMR spectra were acquired on a Bruker Avance III 400 spectrometer spectrometer (Karlsruhe, Germany) with TMS as an internal standard. 1H-1H DQF-COSY, NOESY, TOCSY, HSQC and HMBC spectra were recorded using standard Bruker programs spectrometer (Topspin 3.5pl6, Karlsruhe, Germany). Middle pressure liquid chromatography (MPLC) was carried out on a BUCHI apparatus spectrometer (BUCHI LABORTECHNIK AG, Flawil, Switzerland) equipped with a C-605 pump and open chromatographic columns of different specifications (without detector). Thin layer chromatography (TLC) analysis was performed on alumina plates coated with silica gel 60 and silica gel 60 RP-18 F254 (Merck) spectrometer (Darmstadt, Germany). Chromatographic separation was performed on self-packed columns with silica gel (Anhui Liangchen Silicon Material Co. Ltd., China) and reversed-phase silica gel (ODS-A 12 nm S-50 μm YMC Co., Kyoto, Japan). AChE (EC 3.1.1.7, from electric eel), BChE (EC 3.1.1.8, from equine serum), 5,5′-dithiobis(2-nitrobenzoic acid) (DTNB), acetylthiocholine iodide (ATCI), and butyrylthiocholine iodide (BTCI) were purchased from Sigma-Aldrich (St. Louis, MO, USA).
+ Open protocol
+ Expand
2

Analytical Techniques for Organic Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The chemical reactions were monitored by TLC using commercially available alumina plates coated with silica gel 60 F254 (Merck). Chromatographic separation was performed on self-packed columns with silica gel from Qingdao Haiyang Chemical Group Co., Ltd. (PR China), and MPLC was carried out on a BUCHI apparatus equipped with a C-605 pump. 1H and 13C NMR spectra were recorded on a Bruker Avance III 400 spectrometer with TMS as an internal standard. Coupling constant (J) values were presented in Hz, and spin multiplicities were given as s (singlet), d (doublet), t (triplet), q (quartet), br.s (broad singlet) and m (multiplet). A Waters Acquity UPLC Class I/Xevo G2Q-Tof mass spectrometer was used to obtain the high-resolution ESI-MS (HR-ESI-MS) data.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!